Results 41 to 50 of about 1,497,170 (197)
A obstrução da via de saída do ventrículo direito (VSVD) tem gerado muita polêmica em torno da técnica da sua correção cirúrgica, sendo a reconstituição ainda motivo de controvérsias.
Miguel A Maluf +11 more
doaj
The choosing of optimal cell parameters of transcatheter aortic valve prosthesis [PDF]
This paper presents the analysis of dependences between frame basic cell geometry parameters and function via finite element analysis. The simplified models of frame cell with varied strut width, thickness and quantity in a circle was researched to ...
Evgeny Andreevich Ovcharenko +4 more
doaj +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
Retroca valvular Replacement of heart valves prostheses
A reoperação de próteses valvulares tem sido realizada, com freqüência cada vez maior, nos vários Serviços de cirurgia cardíaca. Os detalhes do tratamento, a indicação e a técnica operatória melhoraram os resultados. No período de janeiro de 1984 a junho
Pablo M. A Pomerantzeff +12 more
doaj
To the Editor: We appreciate Kealhofer and colleagues’ report on their beneficial use of cardiac computed tomography (CT) for evaluating prosthetic aortic valve dysfunction.1 We want to contribute further by drawing attention to the role of cardiac CT in
Güner, Ahmet +3 more
core +1 more source
Bioengineered self-seeding heart valves [PDF]
ObjectiveMechanical and biological prostheses are used to replace damaged heart valves but are associated with significant morbidities. Although there is increased interest in bioengineering cell-seeded heart valve scaffolds, it is a time-consuming and ...
Lee, Sang-Jin +11 more
core +1 more source
Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon
ABSTRACT Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury.
Anne Venkata Ganeshkumar +5 more
wiley +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source
Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton +3 more
wiley +1 more source
Transthoracic three-dimensional echocardiography for the assessment of straddling tricuspid or mitral valves [PDF]
Background The advent of 3D echocardiography has provided a technique which, potentially, could afford significant additional information over conventional cross-sectional echocardiography in the assessment of patients with straddling atrioventricular ...
Anderson, RH +3 more
core

