Results 51 to 60 of about 23,964 (261)

Asymptotics of the heat exchange

open access: yesJournal of Functional Analysis, 2004
If \(K\subset \mathbb R^{m}\) is a compact subset, we set \(E_{K}(t) = \int_{\mathbb R^{m}\setminus K} u(x,t)\,\roman dx\), where \(u\) is the (unique) weak solution to the heat equation \(\partial_{t}u = \Delta u\) in \((\mathbb R^{m}\setminus K)\times \mathbb R_+\) with initial condition \(u(\cdot,0) = 0\) and boundary condition \(u=1\) on \(\partial
openaire   +3 more sources

Analysis of Heat Exchange Performance of Heat Exchange Tubes of Evaporative Heat Exchanger Based on Fluent

open access: yesIOP Conference Series: Earth and Environmental Science, 2020
AbstractIn order to study the influence of the heat exchange tubes length of the evaporative heat exchanger on the heat exchange performance of the organic Rankine cycle technology (ORC) in automobile exhaust heat recovery, four kinds of three-layer tube heat exchange tube models with the length of 500mm, 800mm, 1100mm and 1400mm are designed by DM ...
Changting Li, Fan Bai, Fanghuai Gou
openaire   +1 more source

NFDI MatWerk Ontology (MWO): A BFO‐Compliant Ontology for Research Data Management in Materials Science and Engineering

open access: yesAdvanced Engineering Materials, EarlyView.
This article presents the NFDI‐MatWerk Ontology (MWO), a Basic Formal Ontology‐based framework for interoperable research data management in materials science and engineering (MSE). Covering consortium structures, research data management resources, services, and instruments, MWO enables semantic integration, Findable, Accessible, Interoperable, and ...
Hossein Beygi Nasrabadi   +4 more
wiley   +1 more source

Studi Eksperimen Analisa Performa Compact Heat Exchanger Louvered Fin Flat Tube untuk pemanfaatan Waste Energy

open access: yesJurnal Teknik ITS, 2014
Waste Heat Recovery merupakan instalasi yang digunakan untuk memanfaatkan kembali waste energy seperti exhaust gas. Penelitian dilakukan pada compact heat exchanger tipe louvered fin flat tube sebagai salah satu komponen penyusun waste heat recovery ...
Taqwim Ismail   +1 more
doaj  

Preliminary Design Optimization of 2 K Superfluid Helium Plate-fin Heat Exchanger in Kilowatt Scale

open access: yesYuanzineng kexue jishu, 2022
The 2 K cryogenic system is a key subsystem of the new generation superconducting accelerator, and the 2 K heat exchanger is the key equipment. With the increasing scale of 2 K cryogenic system, the demand for high-flow 2 K heat exchanger becomes more ...
ZHU Keyu;CHANG Zhengze;LI Mei;LI Shaopeng;SUN Liangrui;SANG Minjing;YE Rui;ZHOU Jianrong;PAN Weimin;GE Rui
doaj  

A Simplified Laminar Flow Model for the Pultrusion of Glass Fiber/Polyethylene Terephthalate Commingled Yarns

open access: yesAdvanced Engineering Materials, EarlyView.
A simplified thermoplastic pultrusion model is developed to predict thermal fields in glass fiber/polyethylene terephthalate (GF/PET) composites with reduced computational cost. By combining effective material homogenization, validation against literature data, and Gaussian‐process‐based optimization, the study reveals how heating limits, pulling speed,
Elder Soares   +3 more
wiley   +1 more source

Optimization on Scheduling for Cleaning Heat Exchangers in the Heat Exchanger Networks

open access: yesChemical Engineering Transactions, 2015
In the process at a plant that incorporating heat integration for energy recovery, fouling or formation of deposits on the heat exchanger often causes operational problems in production. Increasing the energy consumption resulted in higher operating expenses. Expenses can be reduced if the cleaning is done on a regular basis. Therefore, how to schedule
Licindo D., Handogo R., Sutikno J.P.
openaire   +2 more sources

Fostering Innovation: Streamlining Magnetocaloric Materials Research by Digitalization

open access: yesAdvanced Engineering Materials, EarlyView.
Magnetocaloric cooling (MCE) is an environmentally friendly refrigeration method with great potential. Optimizing MCE materials involves the preparation and screening of large quantities of samples, which in turn generates a large amount of data. A digitalization approach is presented that uses ontologies, knowledge graphs, and digital workflows to ...
Simon Bekemeier   +17 more
wiley   +1 more source

Feasibility Study of the Ø5 Tube-and-fin Heat Exchanger in Automotive Heat Pump System

open access: yesZhileng xuebao, 2013
The parallel flow microchannel (PFM) heat exchanger is widely used in automotive air conditioning system, but it has the disadvantage of easy-frost and difficult in water-drain in defrost .
Wei Wei   +4 more
doaj  

Preliminary Design and Analysis of Regenerative Heat Exchanger

open access: yesChemical Engineering Transactions, 2016
Heat regenerators transfer heat from one gas to another, with by storage in solids. This type of heat exchanger is used primarily when heat has to be transferred between enormous amounts of gases, when the gases are dirty and liable to plug up the ...
B. Kilkovský, Z. Jegla
doaj   +1 more source

Home - About - Disclaimer - Privacy