Results 31 to 40 of about 63,706 (311)
Asymptotics of the heat exchange
If \(K\subset \mathbb R^{m}\) is a compact subset, we set \(E_{K}(t) = \int_{\mathbb R^{m}\setminus K} u(x,t)\,\roman dx\), where \(u\) is the (unique) weak solution to the heat equation \(\partial_{t}u = \Delta u\) in \((\mathbb R^{m}\setminus K)\times \mathbb R_+\) with initial condition \(u(\cdot,0) = 0\) and boundary condition \(u=1\) on \(\partial
openaire +3 more sources
We identified a systemic, progressive loss of protein S‐glutathionylation—detected by nonreducing western blotting—alongside dysregulation of glutathione‐cycle enzymes in both neuronal and peripheral tissues of Taiwanese SMA mice. These alterations were partially rescued by SMN antisense oligonucleotide therapy, revealing persistent redox imbalance as ...
Sofia Vrettou, Brunhilde Wirth
wiley +1 more source
Analysis of ground massif temperatures with horizontal heat exchanger
The paper is aimed at specification of ground massif temperatures in the horizontal heat exchanger area in both the heating season and during heat exchanger stagnation.
M. Šeďová +2 more
doaj +1 more source
In order to improve the heat transfer efficiency of air cooled high voltage motor heat exchanger, this paper takes 500 kW high voltage motor heat exchanger as the research object, and establishes the mathematical model and physical model of the heat ...
Jinhui Liu, Mengmeng Ai
doaj +1 more source
Biomolecular condensates formed by fused in sarcoma (FUS) are dissolved by high ATP concentrations yet persist in cells. Using a reconstituted system, we demonstrate that valosin‐containing protein (VCP), an AAA+ ATPase, counteracts ATP‐driven dissolution of FUS condensates through its D2 ATPase activity.
Hitomi Kimura +2 more
wiley +1 more source
Evaluation of the using Al2O3/EG and TiO2/EG nanofluids as coolants in the double-tube heat exchanger [PDF]
: In this study, Al2O3/EG and TiO2/EG nanofluids as coolants have been used in the double-tube heat exchanger. The hot solvent inlet heat exchanger must be cooled down with a specified amount.
Navid Bozorgan
doaj
Flow prediction, heat transfer pattern, and thermo-hydraulic efficiency in a heat exchanger tube fitted with vortex generator are chosen for the present research. The 30° inclined ring is opted to develop the performance of the heat exchanger tube.
Amnart Boonloi +1 more
doaj +1 more source
Degradation mechanism of the von Willebrand factor A2 domain by nattokinase
Nattokinase, a natto‐derived protease, exhibits potent antithrombotic effects. This study demonstrates that nattokinase directly cleaves the von Willebrand factor (vWF) A2 domain in vitro. Unlike the native regulator ADAMTS13, nattokinase degrades folded vWF independently of shear stress.
Ryuichi Hyakumoto +3 more
wiley +1 more source
Pressure drop in the heat exchanger is a key issue that should be considered in the HEN retrofit, as increasing the pressure of fluid can cost a substantial amount of energy. To accurately estimate the cost-related trade-off factors, the relative cost of
Bohong Wang +3 more
doaj +1 more source
An unexpected alternative interaction site for ethyl viologen was identified in formate dehydrogenase 1 from Methylorubrum extorquens. Combined mutagenesis, kinetic analysis, and docking revealed that aromatic residues near an iron–sulfur cluster enable flavin mononucleotide‐independent electron transfer, offering a framework for engineering improved ...
Eleni G. Poloniataki, Yong Hwan Kim
wiley +1 more source