Results 91 to 100 of about 193,024 (266)

The effect of nozzle inclination on heat transfer in jet impingement systems [PDF]

open access: yes, 1981
Jet impingement heating and cooling techniques are used extensively in industrial applications. in some of these installations, the axis of the jet can be inclined relative to the impingement surface.
Oladiran, M. T.
core  

THE EFFECT of the USE of DIFFERENT NANOFLUIDS on the HEAT TRANSFER PERFORMANCE of a HEAT EXCHANGER

open access: yes, 2022
The most important problem of heating and cooling systems is the removal of heat from the system. Heat exchangers are the most critical equipment of such systems. However, the use of nanofluids has increased significantly in recent years due to the design limitation of heat exchangers. In this study, the effect of using different nanofluids on the heat
openaire   +3 more sources

Aquaporin‐3 and aquaporin‐5 impact the development of pancreatic ductal adenocarcinoma spheroids

open access: yesFEBS Open Bio, EarlyView.
Schematic representation of the role of aquaporin‐3 (AQP3) and aquaporin‐5 (AQP5) in pancreatic ductal adenocarcinoma (PDAC). Both proteins are upregulated in PDAC and are associated with tumor progression and metastatic potential. Silencing AQP3 or AQP5 in PDAC spheroids results in decreased diameter, area, and overall growth, underscoring their key ...
Catarina Pimpão   +3 more
wiley   +1 more source

Dose‐dependent hepatotoxicity of hydrogen peroxide in HepG2 cells and its modulation by CYP450 induction

open access: yesFEBS Open Bio, EarlyView.
NMR metabolomics revealed concentration‐dependent metabolic perturbations in HepG2 cells exposed to H2O2. Rifampicin pretreatment enhanced metabolic competence, attenuated toxin‐induced alterations and produced metabolite profiles more consistent with human liver physiology, supporting the use of CYP450‐induced HepG2 models for improved in vitro ...
Maren Jinks   +4 more
wiley   +1 more source

Condensation heat transfer and pressure drop in flat tubes having different aspect ratio

open access: yes, 2012
In this study, condensation heat transfer coefficients of R-410A were obtained in flattened stainless tubes made from 5.0 mm inner diameter round tubes.
Kim, Nae-Hyun   +2 more
core  

Heat transfer performance of a wickless heat pipe.

open access: yesTRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B, 1985
KOBAYASHI, Kazuki   +3 more
openaire   +2 more sources

Feasibility and Tolerability of Performing Portable MRI for Neurological Disorders in an Outpatient Neurology Clinic: A Prospective Cohort

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Accessing brain magnetic resonance imaging (MRI) can be challenging, especially for underserved patients, which may lead to disparities in neurological diagnosis. Method This mixed‐methods study enrolled adults with one of four neurological disorders: mild cognitive impairment or dementia of the Alzheimer type, multiple sclerosis ...
Maya L. Mastick   +19 more
wiley   +1 more source

An experimental investigation of structured roughness on heat transfer during single-phase liquid flow at microscale

open access: yes, 2011
This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece.
Lin, TY   +2 more
core  

Experimental Analysis of the performance of fractal stirrers for impinging jets heat transfer enhancement [PDF]

open access: yes, 2014
Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014.A new passive method for the heat transfer enhancement of circular impinging jets is proposed and tested.
CAFIERO, GIOACCHINO   +5 more
core  

GAD65 Antibody ELISA With Extended Reportable Range: Validation and Guidance for Neurological Practice

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To (1) validate GAD65‐ELISA detection and quantification for type 1 diabetes mellitus and autoimmune neurological diagnoses, (2) correlate ELISA results (reference range < 5 IU/mL) with established radioimmunoprecipitation assay (RIA; ≤ 0.02 nmol/L), and (3) define ELISA clinical utility and pitfalls.
Andrew McKeon   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy