Results 91 to 100 of about 519,711 (283)
A type of magnetically responsive artificial cells (ACs) has been developed, demonstrating the loading of mitochondria and self‐enclosure processes to ensure the protection of mitochondrial transport via the bloodstream. The treatment with ACs effectively transplanted mitochondria around the lesion, thereby improving neurological recovery by supporting
Mi Zhou +10 more
wiley +1 more source
ObjectiveTo investigate the feasibility and performance of 4D flow MRI accelerated by compressed sensing (CS) for the hemodynamic quantification of intracranial artery and venous sinus.Materials and methodsForty healthy volunteers were prospectively ...
Jiajun Cao +7 more
doaj +1 more source
Deployable 3D‐Printed Vascular Stent with Surface‐Catalysed Endogenous Nitric Oxide Generation
A deployable 3D‐printed vascular stent was fabricated with surface‐catalyzed endogenous nitric oxide generation, representing a promising new direction for stent development. The stent can be remotely controlled by magnetic force in its compressed state and fully deployed at the target site using an untethered heat source, potentially eliminating the ...
Kun Zhou +8 more
wiley +1 more source
Transversus abdominis plane block reduces remifentanil and propofol consumption, evaluated by closed-loop titration guided by bispectral index. [PDF]
The present prospective, randomized, double-blind study aimed to determine the impact of transversus abdominis plane (TAP) block on propofol and remifentanil consumption, when administered by closed-loop titration guided by processed ...
Jiang, Mei-Ru +7 more
core
This review explores the integration of microfluidic technology with organoid systems as an innovative platform for studying menopausea complex multi‐organ condition. By enabling precise simulation of inter‐organ communication and hormone responses, microfluidic organoids offer a physiologically relevant model for investigating menopausal syndrome and ...
Qianyi Zhang +4 more
wiley +1 more source
Isometric exercise-induced hemodynamic load strongly predicts left ventricular mass in hypertension [PDF]
C
Chirinos, Julio +8 more
core +1 more source
Non‐Invasive Multidimensional Capacitive Sensing for In Vivo Traumatic Brain Injury Monitoring
Single‐electrode, multidimensional capacitive sensors noninvasively assess cerebral autoregulation and compliance for traumatic brain injury monitoring. ABSTRACT Traumatic brain injury (TBI) is a major cause of death and disability, but invasive intracranial pressure (ICP) monitoring is risky, and current non‐invasive methods lack the resolution and ...
Shawn Kim +8 more
wiley +1 more source
A high‐density wearable body‐surface potential mapping array reveals how gravity reshapes cardiac conduction in real time. By resolving spatiotemporal delay patterns invisible to conventional ECG, the platform uncovers posture‐dependent electrophysiological adaptations across the thorax.
Ruben Ruiz‐Mateos Serrano +4 more
wiley +1 more source
Immediate management of a stable patient with unstable pelvis
The diagnosis of a traumatic unstable pelvis in a stable patient is a temporary concept depending on when we see the patient, as all patients presenting with hemorrhagic shock have hemodynamic stability until they become unstable.
Juan Ramón Cano +3 more
doaj +1 more source
This work presents a fully synthetic, 3D‐printed dynamic heart model with left‐side anatomy featuring sutured mitral valve chordae tendineae analogs, embedded actuators for physiologic wall contraction, and customized flexible pressure sensors for the left ventricle.
Alejandro Guillen Obando +7 more
wiley +1 more source