Investigation on the fault monitoring of high-voltage circuit breaker using improved deep learning. [PDF]
Mechanical faults are the main causes of abnormal opening, refusal operation, or malfunction of high-voltage circuit breakers. Accurately assessing the operational condition of high-voltage circuit breakers and delivering fault evaluations is essential ...
Hao Chen +5 more
doaj +2 more sources
Mechanical Fault Diagnosis of a High Voltage Circuit Breaker Based on High-Efficiency Time-Domain Feature Extraction with Entropy Features [PDF]
The fault samples of high voltage circuit breakers are few, the vibration signals are complex, the existing research methods cannot extract the effective information in the features, and it is easy to overfit, slow training, and other problems.
Jiajin Qi, Xu Gao, Nantian Huang
doaj +2 more sources
Research on fault identification of high-voltage circuit breakers with characteristics of voiceprint information [PDF]
High voltage circuit breakers are one of the core equipment in power system operation, and the voiceprint signals generated during operation contain extremely rich information.
Sihao Wang, Yongrong Zhou, Zhaoxing Ma
doaj +2 more sources
Research on the Difference Mechanism of High Voltage Circuit Breaker’s Opening/Closing Coil Current [PDF]
High voltage circuit breakers are important protection and control equipment for the power grid. The defects and faults of the circuit breaker seriously affect the safety and stability of the power system.
Su Yi, Lu Yufeng, Zhang Lei, Rao Xiajin
doaj +1 more source
Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high‐voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are
Jixing Sun +8 more
doaj +1 more source
Design of ± 535 kV hybrid high voltage direct current (HVDC) circuit breaker
This paper proposes a ± 535 kV hybrid high voltage direct current (HVDC) circuit breaker. In this paper, the interruption processes of the main branch, transferring branch, and MOV (metal oxide varistors) branch are studied by PSCAD/EMTDC computer ...
Chenyang Liu +4 more
doaj +1 more source
An essential piece of equipment for the protection and management of the electricity grid is a high voltage(HV) circuit breaker. The reliability and stability of the electricity grid are directly affected by the condition of operation of a high voltage ...
Kuan Zhang +3 more
doaj +1 more source
Parameters design of voltage sharing components for the series multi‐break mechanical switch
Series multi‐break mechanical switch is one of the critical components of high‐voltage hybrid DC circuit breakers. However, due to the existence of distributed capacitance, the voltage distribution between the breaks is not balanced.
Daochun Huang +5 more
doaj +1 more source
This paper presents a design and performance evaluation of three different overvoltage suppression circuits employed in a solid-state circuit breaker for medium- to high-power and low- to medium-voltage DC grids.
Andreas Giannakis, Dimosthenis Peftitsis
doaj +1 more source
Real-Time Monitoring of High Voltage Switch Based on CAD
In the process of online real-time monitoring of intelligent digital filter high-voltage switchgear, the mechanical state diagnosis of high-voltage circuit breaker is based on fully understanding the mechanical characteristics of each component of ...
Long Di +5 more
doaj +1 more source

