Results 21 to 30 of about 15,608,816 (291)

Optical fiber imaging for high speed plasma motion diagnostics: applied to low voltage circuit breakers [PDF]

open access: yes, 2010
An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs.
Tribulato, G.   +9 more
core   +1 more source

Arc root commutation from moving contacts in low voltage devices [PDF]

open access: yes, 2000
This paper focus on the arc commutation from a moving contact and in particular on the anode motion of a high current arc in low voltage current limiting circuit breakers.
Weaver, P.M.   +5 more
core   +1 more source

Research on circuit breaker failure protection and the secondary accelerated fault isolation scheme of VSC-HVDC grids

open access: yesFrontiers in Energy Research, 2023
When the direct current circuit breaker (DCCB) fails to operate, the fault range will further expand, endangering the safe operation of the power gird.
Andi Li   +4 more
doaj   +1 more source

The energetics of gas flow and contact erosion during short circuit arcing [PDF]

open access: yes, 2004
The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete.
Weaver, P.M.   +2 more
core   +1 more source

Arc motion and gas flow in current limiting circuit breakers operating with a low contact switching velocity [PDF]

open access: yes, 2002
Arc motion in low voltage (240 VAC) high current (10/sup 3/-10/sup 4/A.) current limiting-circuit breakers is dominated by arc root mobility. The mobility is influenced by the gas flow and gas composition in the contact region, but there is little ...
Weaver, P.M.   +2 more
core   +1 more source

Influence of single-phase circuit breaker tripping on inverter commutation

open access: yes电力工程技术, 2022
If commutation failure does not occur when single-phase high resistance grounded in single-circuit AC line of inverter,then single-phase circuit breaker tripping may lead to commutation failure.
SONG Xinfu   +4 more
doaj   +1 more source

Arc root mobility on piezoelectrically actuated contacts in miniature circuit breakers [PDF]

open access: yes, 2005
A novel contact opening mechanism has been developed using a piezoelectric actuator to open the contacts in a low contact opening velocity circuit breaker.
Weaver, P.M.   +5 more
core   +1 more source

Research on transient insulation numerical analysis method of circuit breaker in GIS under lightning impulse voltage

open access: yesThe Journal of Engineering, 2019
In order to reveal the process of insulation destruction of circuit breaker in GIS under lightning impulse voltage, a new method of transient insulation numerical analysis is described in this paper.
Wu Qi   +3 more
doaj   +1 more source

Structural diagram of high-voltage circuit breaker.

open access: yes, 2023
Structural diagram of high-voltage circuit breaker.
Yucheng Zhang (136327)   +5 more
core   +1 more source

Research on the Reliability Test and Life Assessment Methods of Relays Used in Circuit Breaker Operating Mechanism

open access: yes, 2023
As one of the key components of the circuit breaker operating mechanism, the relay can experience performance degradation due to harsh environmental factors, such as salt spray, during operation, which can ultimately affect the normal operation of the ...
Chao Gao   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy