Results 31 to 40 of about 18,117,125 (296)
The high amplitude and steep overvoltage generated by the breaking of the vacuum circuit breaker in the wind farm damages the inter-turn insulation of the transformer.
Ziheng Pu +4 more
core +1 more source
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source
As one of the key components of the circuit breaker operating mechanism, the relay can experience performance degradation due to harsh environmental factors, such as salt spray, during operation, which can ultimately affect the normal operation of the ...
Chao Gao +5 more
core +1 more source
Development of non-intrusive monitoring for reactive switching of high voltage circuit breaker
High-voltage circuit breakers are among the most important equipments for ensuring the efficient and safe operation of an electric power system. On occasion, circuit breaker operators may wish to check whether equipment is performing satisfactorily and ...
Pater, Ryszard +6 more
core +1 more source
The energetics of gas flow and contact erosion during short circuit arcing [PDF]
The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete.
Weaver, P.M. +2 more
core +1 more source
With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability,
Muhammad Junaid +6 more
doaj +1 more source
Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN +4 more
doaj +1 more source
The ubiquitin system in normal and infected germinal center B cells
The ubiquitin system plays a central role in germinal center (GC) B cells, influencing differentiation to long‐lived memory B cells. Oncogenic gammaherpesviruses gain access to memory B cells by establishing latency in GC B cells. Mapping ubiquitin mechanisms in normal and infected GC B cells will define specific molecular circuits in B cells germane ...
Destiny Davis +2 more
wiley +1 more source
High voltage circuit breaker (CB) is one of the most important components in high voltage circuit. In the process of operation, some kinds of mechanical faults such as jam fault, component deformation and component failure may occur and affect the ...
Y. Pan, K. Zhao, X. D. Liu, J. G. Yang
core +1 more source
Analysis of SF6 contact based on QPSO-SVR
In the condition evaluation of the high-voltage SF6 circuit breaker, contact resistance and mass loss have a significant impact on the arc contact. To that end, this paper proposes a method based on quantum particle swarm optimization and support vector ...
Jianwei Bai +6 more
doaj +1 more source