Results 11 to 20 of about 1,128 (267)
New two chamber transfer switch for 6500 A commutation current
HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmission systems, which increased to 6,400A ...
Lutz-Rüdiger Jänicke +4 more
doaj +1 more source
When the direct current circuit breaker (DCCB) fails to operate, the fault range will further expand, endangering the safe operation of the power gird.
Andi Li +4 more
doaj +1 more source
Influence of single-phase circuit breaker tripping on inverter commutation
If commutation failure does not occur when single-phase high resistance grounded in single-circuit AC line of inverter,then single-phase circuit breaker tripping may lead to commutation failure.
SONG Xinfu +4 more
doaj +1 more source
In order to reveal the process of insulation destruction of circuit breaker in GIS under lightning impulse voltage, a new method of transient insulation numerical analysis is described in this paper.
Wu Qi +3 more
doaj +1 more source
Fault Interruption Scheme for HVDC System Using SiC-MESFET and VCB Based Hybrid Circuit Breaker
As high voltage DC power system is gaining popularity, power electronic switching devices are becoming increasingly advanced to overcome problems of timely fault isolation.
Waheed A. Khan +6 more
doaj +1 more source
Simulation of supersonic flow in high-voltage circuit breakers
High-voltage circuit breakers (HVCB) are critical protection and control equipment in the electric transmission and distribution system. Analysis of the arc quenching process in the nozzle through modelling and simulation is a key stage in the development process of the HVCB.
Qiao, Yujiao +2 more
openaire +2 more sources
The development of power grid system not only increases voltage and capacity, but also increases power risk. This paper briefly introduces the feature extraction method of the vibration signal of high voltage circuit breaker and support vector machine ...
Li Long +4 more
doaj +1 more source
Basic contents of on-line monitoring technologies of mechanical characteristics of high-voltage vacuum circuit breaker were introduced, and various kinds of methods of on-line monitoring were reviewed.
ZHAO Yang
doaj +1 more source
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source
Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN +4 more
doaj +1 more source