Results 31 to 40 of about 49,234 (298)

Influence of Sheds Damage on the AC Pollution Flashover Performance of Different Voltage Class Composite Insulators

open access: yesIEEE Access, 2020
The damage of high-voltage terminal shed of composite insulators can influence the flashover performance of the insulators. The study was carried out experimentally to investigate the flashover characteristics of composite insulators with sheds damage at
Lu Ming, Li Yangyang, Hu Jianlin
doaj   +1 more source

Mechanism of saline deposition and surface flashover on high-voltage insulators near shoreline:mathematical models and experimental validations [PDF]

open access: yes, 2019
This paper deals with sea salt transportation and deposition mechanisms and discusses the serious issue of degradation of outdoor insulators resulting from various environmental stresses and severe saline contaminant accumulation near the shoreline.
Chaudhary, Muhammad Akmal   +2 more
core   +2 more sources

Global experience of HVDC composite insulators in outdoor and indoor environment

open access: yesReviews on Advanced Materials Science, 2020
High-voltage direct current (HVDC) transmission is known as green-energy transfer technology and has recently become an attractive alternative of high-voltage alternating current (HVAC) due to its high-power transmission capability and lower power loss ...
Akbar Mohammad, Mehmood Basharat
doaj   +1 more source

Particle swarm optimization of a neural network model for predicting the flashover voltage on polluted cap and pin insulator

open access: yesDiagnostyka, 2022
This paper proposes training an artificial neural network (ANN) by a particle swarm optimization (PSO) technique to predict the flashover voltage of outdoor insulators.
Belkebir Amel   +2 more
doaj   +1 more source

Monitoring insulator contamination level under dry condition with a microwave reflectometer [PDF]

open access: yes, 2015
—Build-up of surface contamination on high voltage insulators can lead to an increase in leakage current and partial discharge, which may eventually develop into flashover. Conventional contamination level monitoring systems based on leakage current,
Jiang, Yan   +5 more
core   +1 more source

Using contactless methods of diagnostics of high electric fields

open access: yesИзвестия высших учебных заведений: Проблемы энергетики, 2019
In the electric power industry of Russia and abroad, special attention is paid to the problem of an increase in the number of accidents caused by damage to high-voltage insulators in high-voltage equipment.
A. V. Golenischev-Kutuzov   +3 more
doaj   +1 more source

High voltage insulation properties of HFO1234ze [PDF]

open access: yesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
ISSN:1558 ...
Koch, Myriam, Franck, Christian
openaire   +1 more source

Monitoring contamination level on insulator materials under dry condition with a microwave reflectometer [PDF]

open access: yes, 2016
Current techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and infrared, are not effective in dry conditions since they require the surface of the insulator to be wetted by fog, rain or snow. If
Jiang, Y.   +5 more
core   +1 more source

Case Study: Optimizing Grading Ring Design for High Voltage Polymeric Insulators in Power Transmission Systems for Enhanced Electric Field and Voltage Distribution by Using a Finite Element Method

open access: yesEnergies, 2023
This research paper aims to investigate the optimal design of grading rings for high-voltage polymeric insulators in an actual power transmission system, with a focus on improving the electrical representation of the insulator strings.
Esraa Aziz   +3 more
doaj   +1 more source

Ferromagnetic barrier induced negative differential conductance on the surface of a topological insulator [PDF]

open access: yes, 2014
We theoretically investigate the effect of the negative differential conductance of a ferromagnetic barrier on the surface of a topological insulator. Due to the changes of the shape and position of the Fermi surfaces in the ferromagnetic barrier, the ...
An, Xing-Tao
core   +2 more sources

Home - About - Disclaimer - Privacy