Results 91 to 100 of about 33,884,561 (405)
This paper introduces a method for calibrating radar sensors in a multi-sensor cinemometer system using a reference cinemometer based on CW Doppler radar. The method involves synchronizing sensors, pairing data with reference measurements, and performing
Seif Ben-Hassine +4 more
doaj +1 more source
Dealing with co‐channel interference in multi‐channel airborne passive radar
We address the problem of co‐channel interference (CCI) in multi‐channel airborne passive radars using digital broadcast signals of opportunity. A framework for suppressing the CCI is proposed, based on a two‐stage approach, which reflects the range ...
Diego Cristallini +4 more
doaj +1 more source
ABSTRACT Purpose Although not always achieved, complete chemotherapy‐induced nausea and vomiting (CINV) control is the conventional goal of CINV prophylaxis. In this two‐center, mixed‐methods study, we sought to understand the preferences of adolescent patients and family caregivers for CINV control endpoints.
Haley Newman +8 more
wiley +1 more source
This article presents a study on interferometric inverse synthetic aperture radar (ISAR) for three‐dimensional imaging and rotational velocity estimation.
Manjunath Thindlu Rudrappa +3 more
doaj +1 more source
Parametric Nanomechanical Amplification at Very High Frequency [PDF]
Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS).
Feng, X. L. +2 more
core +1 more source
Intravitreal GD2‐Specific Chimeric Antigen Receptor T‐Cell Therapy for Refractory Retinoblastoma
ABSTRACT Effective treatments for advanced, treatment‐resistant retinoblastoma (RB) remain limited. GD2‐specific chimeric antigen receptor (CAR) T cells show potent antitumor activity with minimal toxicity but have not previously been evaluated in RB.
Subongkoch Subhadhirasakul +13 more
wiley +1 more source
Cryogenic InP HEMTs With Enhanced
Cryogenic InP High-electron-mobility transistors (HEMTs)-based low-noise amplifiers (LNAs) have been applied in deep space exploration, which demands high performance from InP HEMTs.
Yuxuan Chen +7 more
doaj +1 more source
Spectral variability in faint high frequency peakers [PDF]
We present the analysis of simultaneous multi-frequency Very Large Array (VLA) observations of 57 out of 61 sources from the ``faint'' high frequency peaker (HFP) sample carried out in various epochs.
Abazajian +33 more
core +1 more source
High frequency temperature variability reduces the risk of coral bleaching
Coral bleaching is the detrimental expulsion of algal symbionts from their cnidarian hosts, and predominantly occurs when corals are exposed to thermal stress. The incidence and severity of bleaching is often spatially heterogeneous within reef-scales (
Aryan Safaie +8 more
semanticscholar +1 more source
Outcomes of Live Virus Vaccination in Patients With Vascular Anomalies Being Treated With Sirolimus
ABSTRACT Background Live vaccination in patients with vascular anomalies (VA) receiving sirolimus remains controversial due to immunosuppressive effects and theoretical risks. Procedure This single‐center retrospective study included patients with VA less than 4 years old at the start of sirolimus therapy who were incompletely vaccinated.
Svatava Merkle +5 more
wiley +1 more source

