Impact of Transformer Grounding On TRV During Inductive Load Switching at Transmission and Substation Service Unit (ULTG) Maros

open access: yesJurnal Nasional Teknik Elektro
This paper investigates the impact of transformer grounding configurations on Transient Recovery Voltage (TRV) during fault current interruption in high-voltage power systems. The study evaluates three grounding schemes: Solid–Solid, Solid–Floating, and
Muhammad Khaidir   +5 more
doaj   +1 more source

Hydrogen‐Assisted Fracture of Iron‐Based Fe–Ni–Al Alloys

open access: yesAdvanced Engineering Materials, EarlyView.
Principal relations and fracture mechanisms of single‐phase and precipitate‐strengthened Fe–Ni–Al alloys subjected to prior electrochemical hydrogen charging are identified. The mechanisms of hydrogen effect on strength and microhardness are discussed, including hydrogen‐induced increase in microhardness and the role of hydrogen in fracture behavior ...
Nataliya Yadzhak   +3 more
wiley   +1 more source

Single-Pole High-Resistance Grounding Protection for DC Distribution Lines Based on Current Integral Quantity Correlation

open access: yesZhongguo dianli
When a single-pole high-resistance grounding fault occurs in a DC distribution system, the transient current amplitude is small and the fault characteristics are weak, making it hard for the existing protection methods to provide reliable protection for ...
Xingquan JI   +6 more
doaj   +1 more source

Creep‐Induced Microstructural Evolution in an A2‐B2 Superalloy

open access: yesAdvanced Engineering Materials, EarlyView.
A 27.3Ta‐27.3Mo‐27.3Ti‐8Cr‐10Al (at.%) refractory high‐entropy alloy with precipitation‐strengthened A2‐B2 microstructure was studied by creep tests at 1030°C, which demonstrate a transition in deformation mechanisms in the range of 100–150 MPa applied stress. This is associated with changes in dislocation–precipitate interactions. Relevant deformation
Liu Yang   +10 more
wiley   +1 more source

Influence of Test Temperature and Test Frequency on Fatigue Life of Aluminum Alloy EN AW‐2618A

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of test temperature and test frequency on the fatigue life of EN AW‐2618A is investigated. High‐cycle fatigue tests are performed at different test temperatures and frequencies on the 1000 h/230°C overaged state. Both test parameters reduce fatigue life due to time‐dependent damage mechanisms.
Ying Han   +5 more
wiley   +1 more source

High‐Temperature Nanoindentation of Metals: Assessing Thermal Drift, Frame Compliance, and Chemical Composition Effects on the Reported Mechanical Properties

open access: yesAdvanced Engineering Materials, EarlyView.
Do not let thermal drift and instrument artifacts deceive high‐temperature nanoindentation results. We compare classical Oliver–Pharr and automatic image recognition analyses across steels and a Ni alloy to quantify these effects. Accounting for artifacts reveals systematic softening with temperature, while Cr and Ni additions boost resistance ...
Velislava Yonkova   +2 more
wiley   +1 more source

A Single‐Phase Grounding Fault Line Selection Method for Flexible Grounding Active Distribution Networks Based on the Ratio of Zero‐Sequence Current Changes

open access: yesIET Electric Power Applications
Single‐phase grounding faults (SPGFs), especially high‐resistance faults, significantly weaken the electrical characteristics of active distribution networks (ADNs), thereby posing considerable challenges for faulted line selection (FLS).
Shi Su   +7 more
doaj   +1 more source

Recycling of NiTi Shape Memory Alloys: Fundamental and Technological Aspects of a Vacuum Induction Melting Processing Route

open access: yesAdvanced Engineering Materials, EarlyView.
The present study investigates recycling of NiTi shape memory alloys via vacuum induction melting. An ingot was synthesized from elemental Ni and Ti and subjected to three subsequent remelting cycles. Remelting increases process durations and impurity levels and adversely affects microstructures and functional properties.
Sakia Sophia Noorzayee   +7 more
wiley   +1 more source

Advancing Grounding System Design: A Comprehensive Review of Key Elements, Parameters, and Performance Insights

open access: yesIEEE Access
The design of high-performance grounding systems is a cornerstone of safety and reliability in modern AC substations, particularly under increasingly severe fault and transient operating conditions.
Mahmoud Wahba   +3 more
doaj   +1 more source

Soft Mechanical‐Electrical Logic Using Liquid Metal‐Filled 3D‐Printed Architectures

open access: yesAdvanced Engineering Materials, EarlyView.
We present 3D‐printed soft mechanical–electrical logic elements that use liquid metal–filled silicone tubes actuated by thermoplastic polyurethane/polylactic acid (TPU/PLA) architectures to produce Boolean operations. Complementary normally open and normally closed unit cells perform repeatable binary transitions and can be combined into more complex ...
Christoph Lehmann   +2 more
wiley   +1 more source