Results 51 to 60 of about 44,894 (246)
When a single-pole high-resistance grounding fault occurs in a DC distribution system, the transient current amplitude is small and the fault characteristics are weak, making it hard for the existing protection methods to provide reliable protection for ...
Xingquan JI +6 more
doaj +1 more source
The low cycle fatigue life of additive manufactured HAYNES® 282® superalloy was investigated for conventional and high‐productivity processing: samples of the former lasted 1400–1700 cycles, while samples of the latter failed at ~ 1200 cycles, at 760 °C and 1% strain.
Abdul Shaafi Shaikh +3 more
wiley +1 more source
Fault phase selection of mine power supply system based on frequency distribution theory
In view of the problem of ineffective selection of asymmetric mine neutral point ungrounded system while high resistance grounding occurs, a fault phase selection of mine power supply system based on frequency distribution theory was proposed. Each phase
YU Qun, CHEN Zhihui, HE Ziyua
doaj +1 more source
This article demonstrates the successful qualification of a copper–tungsten composite for laser powder bed fusion. The resulting components exhibited high density, high thermal conductivity, and reduced thermal expansion. Heat sinks with complex geometries were successfully manufactured, clearly showcasing the material's potential for additive ...
Simon Rauh +6 more
wiley +1 more source
Performance Optimization of Grounding System for Multi-Voltage Electrical Installation
Grounding systems are critical for ensuring electrical safety, fault current dissipation, and electromagnetic compatibility in power installations across different voltage levels.
Md Tanjil Sarker +3 more
doaj +1 more source
Dual Channel Control with DC Fault Ride Through for MMC-based, Isolated DC/DC Converter [PDF]
This study is sponsored by the Engineering and Physical Sciences Research Council (EPSRC) grant no EP/K006428/1, 2013.D. Jovcic and H. Zhang are with the School of Engineering, University of Aberdeen, AB24 3UE, U.K.
Jovcic, Dragan, Zhang, Huibin
core +1 more source
Duplex Stainless Steel Laser‐Surface Textured: Stability in Brine Solution
Controlled laser‐surface treatment (LST) of duplex DSS2205 steel is performed to increase its stability in brine solution under cyclic electrochemical assays. The superior protection with respect to flat and smooth panels is attributed to the presence of FeCr2O4 as the main protective oxide layer in the LST surface, after corrosion tests. The stability
Mohammad Rezayat +5 more
wiley +1 more source
Fault Line Selection Method of Small Current Grounding System Based on Deep Learning
At present, the single-phase grounding fault line selection problem of small current grounding system has not been completely solved. In order to improve the success rate of single-phase grounding fault line selection, a new method based on deep learning
Guodong ZHANG, Haitao PU, Kai LIU
doaj +1 more source
The thermal diffusivity of MgO‐C refractories is highly sensitive to sample preparation and processing procedures. In this article, the effects of coking sequence, machining conditions, structural inhomogeneity, and graphite coating application on measurements using laser flash apparatus are systematically investigated.
Luyao Pan +4 more
wiley +1 more source
The arc extinguishing mode of neutral grounding via arc suppression coil (ASC) is widely used in the distribution network. With the increasing application of active intervention type arc extinguishing device (AIT-AED), there is a situation that the AIT ...
Wei Shi +5 more
doaj +1 more source

