Results 21 to 30 of about 2,823 (255)
Abstract To deal with the DC-link overvoltage during high-voltage ride-through (HVRT) of the wind turbine, a coordinated DC-link voltage control (CDVC) scheme is proposed for enhancing the HVRT performance of offshore doubly-fed induction generator (DFIG) wind turbines equipped with the supercapacitor energy storage system (SESS).
Wei, Juan +5 more
openaire +2 more sources
A high proportion of new energy sources are connected to the grid, which not only alleviates the energy shortage, but also brings hidden dangers to the safe and stable operation of the grid. Aiming at the inadequate consideration of uncertainty caused by
Yuhong Zhu +5 more
doaj +1 more source
Analysis of Transient Voltage-Frequency Dynamic Coupling Mechanism of High-Proportion Renewable Energy Sending End System Under Commutation Failure Faults [PDF]
[Objective] Aiming at the new challenge of unclear transient voltage and system frequency operation risks faced by sending-end power systems with a high proportion of renewable energy after commutation failure, this paper reveals the dynamic coupling ...
GAO Shang, YIN Chunya, LIU Wan, LI Xiaozhu, HAN Lu, ZHANG Gaohang
doaj +1 more source
Safety Voltage Control Strategy for High Voltage Ride-Through of Doubly Fed Induction Generator (DFIG) [PDF]
a DFIG high voltage ride-through method with the consideration for the safe operation voltage of the generator unit is proposed in the article. Based on the dynamic reactive support capability of DFIG, during grid voltage swell, the reactive powers outputted by the grid-side converter and the generator stator are concertedly controlled so as to keep ...
openaire +1 more source
With the increase of photovoltaic penetration rate, the fluctuation of photovoltaic power generation affects the reliability of ship power grids. Marine PV grid-connected systems with high penetration rates should generally have a low voltage ride ...
Shihao Wang +3 more
doaj +1 more source
Fault ride-through control strategy of H-bridge cascaded energy storage system [PDF]
The cascaded energy storage system has received extensive attention in areas such as new energy consumption, maintaining stable operation of the power grid, and supporting black start due to its advantages such as high access voltage level, large single ...
Yin Shi +4 more
doaj +1 more source
To enhance the voltage fault ride-through (VFRT) capability of grid-connected photovoltaic (PV) systems under grid voltage faults, this paper proposes an innovative solution using Superconducting Magnetic Energy Storage (SMES).
Hongchong Yang, Maimaitireyimu Abulizi
doaj +1 more source
A Comprehensive Review on Voltage Stability in Wind-Integrated Power Systems
The fast growth of the world’s energy demand in the modernized world has stirred many countries around the globe to focus on power generation by abundantly available renewable energy resources.
Farhan Hameed Malik +6 more
doaj +1 more source
Fault-ride Through Control Strategy of Multi-terminal High Voltage DC Systems
Abstract A coordinate control strategy is proposed to secure fault-ride through (FRT) for voltage source converter (VSC) based multi-terminal high voltage dc transmissions (MTDC) integrating the offshore wind farms (OWFs). The short circuit fault in the ac grid obviously reduces the voltage at the connection point which, in turn, block the power ...
Jing Li +5 more
openaire +1 more source
A Hybrid HVDC Topology Suitable for Large-Scale Pure Clean Energy Power Base Transmission
In order to meet the transmission needs of large-scale pure new energy power bases, after topology comparison, this paper used a hybrid cascaded topology consisting of a line commutated converter (LCC) and a modular multilevel converter (MMC) in the ...
Wenzhe XU, Zheren ZHANG, Zheng XU
doaj +1 more source