Results 11 to 20 of about 313 (109)
Development of HVRT and LVRT Control Strategy for PMSG-Based Wind Turbine Generators
Various challenges are acknowledged in practical cases with high wind power penetration. Fault ride-through (FRT) capability has become the most dominant grid integration requirements for the wind energy conversion system worldwide. The high voltage ride-
Liang Yuan +5 more
doaj +3 more sources
High-voltage Ride Through Strategy for DFIG Considering Converter Blocking of HVDC System
This paper presents a P-Q coordination based highvoltage ride through (HVRT) control strategy for doubly fed induction generators (DFIGs) based on a combined Q-V control and P-V de-loading control.
Changping Zhou +3 more
doaj +3 more sources
Multi-Mode Voltage Sag/Swell Generator Based on Three-Phase Inverter Circuit
The voltage ride through capability of the major auxiliary variable-frequency drive (VFD) in large thermal power plants is the key technical issue of power grid and source coordination.
Qiguo Han +5 more
doaj +1 more source
Mitigation of Harmonics and Inter-Harmonics with LVRT and HVRT Enhancement in Grid-Connected Wind Energy Systems Using Genetic Algorithm-Optimized PWM and Fuzzy Adaptive PID Control [PDF]
© 2021 Author(s). This is the accepted manuscript version of an article which has been published in final form at https://doi.org/10.1063/5.0015579The growing installed wind capacity over the last decade has led many energy regulators to define specific ...
Allali, Ahmed +3 more
core +2 more sources
Integration improvement of DFIG-based wind turbine into the electrical grid [PDF]
[ENG] This doctoral thesis in electrical engineering is presented as five research works linked together by the same theme. Five articles were published in indexed journals.
El Karkri, Yassir
core +1 more source
Power systems are transitioning towards a higher proportion of inverter‐based resources. This leads to the loss of synchronous generators and their associated control mechanisms. To address low inertia challenges, new international fast frequency response services are established, and renewable enabling technologies and sources are investigated to ...
Dlzar Al Kez +3 more
wiley +1 more source
Influence of Converter DC Bus Overvoltage on Wind Turbine High Voltage Ride Through Capabilities
Off-grid occurred in a wind farm caused by converter fault during field test of the DFIG (doubly feed induction generator) high voltage ride through (HVRT) capabilities.
Guangru ZHANG +6 more
doaj +1 more source
Operating Voltage and Frequency Regime Validation of Grid Code Requirements in South Africa
South Africa first implemented rolling blackouts known as load shedding to protect the integrity and maintain stability of their ailing electrical grid over a decade ago. Since then, load shedding has become a daily occurrence, which South Africa plans to alleviate through the addition of grid‐connected renewable generation.
Gideon D. Joubert +2 more
wiley +1 more source
Abstract This paper suggests a new control algorithm for On‐Load Tap Changer (OLTC) of wind farm main transformer that is responsible for voltage regulation of collector network. The conventional control scheme adjusts the voltage of LV side of transformer without considering the wind turbine voltages.
Bakhtyar Hoseinzadeh, Frede Blaabjerg
wiley +1 more source
Wind energy has emerged as a prominent player in the realm of renewable energy sources, both in terms of capacity and technological adaptability. Among the various renewable energy technologies, wind turbine generators stand out as the most widely ...
Sobhy M. Abdelkader +7 more
doaj +1 more source

