Results 11 to 20 of about 27,610,539 (97)
This paper proposes a coordinated control strategy to enhance the low/high‐voltage ride‐through (L/HVRT) capability of grid‐tied micro‐grids (MGs). The novel control scheme, which is based on grid‐following concepts, contains two layers for each power ...
Reza Deihimi Kordkandi +2 more
doaj +2 more sources
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi +7 more
doaj +2 more sources
High Voltage Crossing Strategy of Wind Farm Considering Active and Reactive Coordinated Recovery [PDF]
ObjectivesTo address the serious high voltage ride-through (HVRT) problem faced by wind farms as a result of the large voltage surge at the grid-connected point after a DC fault, a recovery mechanism of “active priority balancing - reactive power dynamic
MO Jisheng +4 more
doaj +2 more sources
The large-scale integration of wind power, photovoltaic systems, and energy storage systems (ESSs) into power grids has increasingly influenced the transient stability of power systems due to their dynamic response characteristics.
Liming Bo +8 more
doaj +2 more sources
Distributed control of a fault tolerant modular multilevel inverter for direct-drive wind turbine grid interfacing [PDF]
Modular generator and converter topologies are being pursued for large offshore wind turbines to achieve fault tolerance and high reliability. A centralized controller presents a single critical point of failure which has prevented a truly modular and ...
Parker, Max, Ran, Li, Finney, Stephen
core +4 more sources
Power systems are transitioning towards a higher proportion of inverter‐based resources. This leads to the loss of synchronous generators and their associated control mechanisms. To address low inertia challenges, new international fast frequency response services are established, and renewable enabling technologies and sources are investigated to ...
Dlzar Al Kez +3 more
wiley +1 more source
Operating Voltage and Frequency Regime Validation of Grid Code Requirements in South Africa
South Africa first implemented rolling blackouts known as load shedding to protect the integrity and maintain stability of their ailing electrical grid over a decade ago. Since then, load shedding has become a daily occurrence, which South Africa plans to alleviate through the addition of grid‐connected renewable generation.
Gideon D. Joubert +2 more
wiley +1 more source
Abstract This paper suggests a new control algorithm for On‐Load Tap Changer (OLTC) of wind farm main transformer that is responsible for voltage regulation of collector network. The conventional control scheme adjusts the voltage of LV side of transformer without considering the wind turbine voltages.
Bakhtyar Hoseinzadeh, Frede Blaabjerg
wiley +1 more source
Wind energy has emerged as a prominent player in the realm of renewable energy sources, both in terms of capacity and technological adaptability. Among the various renewable energy technologies, wind turbine generators stand out as the most widely ...
Sobhy M. Abdelkader +7 more
doaj +1 more source
STATCOM Controller Tuning to Enhance LVRT Capability of Grid‐Connected Wind Power Generating Plants
This paper investigates the utilization of a STATCOM to enhance the LVRT capability of wind power plants (WPPs) during grid faults. The STATCOM under investigation is tuned using the Water Cycle Algorithm (WCA), Particle Swarm Optimization (PSO), and a hybrid algorithm of both WCA and PSO. Simulations are conducted in MATLAB programming software, using
Irene Ndunge Muisyo +3 more
wiley +1 more source