Results 21 to 30 of about 27,610,539 (97)
A synergetic control method is proposed to improve the fault ride through capability of front‐end speed regulation wind turbine (FESRWT). In case of three‐phase short‐circuit fault and single‐phase grounding fault, this method can accelerate the attenuation of stator flux transient component and restrain the fluctuation of rotor speed, make generator ...
Xiaoqing Li +5 more
wiley +1 more source
Voltage dip generator for testing wind turbines connected to electrical networks [PDF]
This paper describes a new voltage dip generator that allows the shape of the time profile of the voltage generated to be configured. The use of this device as a tool to test the fault ride-through capability of wind turbines connected to the electricity
N. Herrero +28 more
core +1 more source
High-voltage ride through strategy for DFIG-based wind farms under bipolar blocking of HVDC system
Excessive reactive power generated by the filter and compensation devices of rectifier station will flow into the AC system when DC bipolar block occurs, which brings a high voltage threat to doubly-fed induction generator (DFIG)-based wind farms at the ...
Ruowei Zhang +3 more
doaj +1 more source
Power quality (PQ) is a key issue, particularly for technologically advanced process equipment, whose performance mainly depends on the quality of supply. Problems with PQ such as voltage swells/sags, interruptions, and harmonics are defined by any voltage, current, or frequency abnormalities causing damage or failure of the end‐user equipment. Outages
Devalraju Prasad +2 more
wiley +1 more source
With the development of renewable energy technology, distributed power supply mode with multi energy and multi-directional power flow including utility grid, renewable energy and energy storage unit has gradually become a research hotspot.
Yanping Zhu +6 more
doaj +1 more source
A static‐commutated device to contain voltage variations for low‐voltage active users
Abstract The ever‐wider spread of distributed generation in distribution systems feeds the increasing demand for voltage regulation in low‐voltage networks. For these distribution grids, characterised by simpler structures than medium voltage systems but with a larger number of buses and feeders, voltage control devices have to guarantee fast and ...
Giovanni Mercurio Casolino +2 more
wiley +1 more source
LVRT and HVRT control strategies of doubly- fed induction generator [PDF]
The Doubly Fed Induction Generator (DFIG) has a high sensitivity to the Grid Faults (GFs), which can cause many problems on the power quality and the production continuity.
El Karkri, Yassir +3 more
core +2 more sources
To deal with the DC-link overvoltage during high-voltage ride-through (HVRT) of the wind turbine, a coordinated DC-link volt10 age control (CDVC) scheme is proposed for enhancing the HVRT performance of offshore doubly-fed induction generator (DFIG) wind
Zhou, Bin +5 more
core +1 more source
High-voltage Ride Through Strategy for DFIG Considering Converter Blocking of HVDC System
This paper presents a P-Q coordination based highvoltage ride through (HVRT) control strategy for doubly fed induction generators (DFIGs) based on a combined Q-V control and P-V de-loading control.
Changping Zhou +3 more
doaj +1 more source
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro +3 more
wiley +1 more source

