Results 21 to 30 of about 76 (75)
Execution of advanced solar‐shunt active filter for renewable power application
Abstract This manuscript proposes a novel Solar‐shunt active filter (solar‐SHAF) controller for improving the power flow in a larger power‐application. The proposed fault and non‐linear detection unit (FANDU) avails faster disturbance detection. A novel FAND regulator (FANDR) is suggested to disconnect the solar power generation from the considered ...
Buddhadeva Sahoo +2 more
wiley +1 more source
Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ...
Yun Wang +4 more
doaj +1 more source
High-voltage Ride Through Strategy for DFIG Considering Converter Blocking of HVDC System
This paper presents a P-Q coordination based highvoltage ride through (HVRT) control strategy for doubly fed induction generators (DFIGs) based on a combined Q-V control and P-V de-loading control.
Changping Zhou +3 more
doaj +1 more source
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi +7 more
doaj +1 more source
Fault ride-through of renewable energy conversion systems during voltage recovery
Asymmetrical voltage swells during recovery of a short-circuit fault lead to fluctuations in the dc-link voltage of a renewable energy conversion system (RECS), and may induce reversed power flow and even trip the RECS. This paper studies characteristics
Ruiqi Li, Hua Geng, Geng Yang
doaj +1 more source
This paper analyses the impact mechanism of renewable energy transient control parameters on power angle stability and transient overvoltage in a generation system with combined renewable energy and conventional thermal power. An optimization method for transient control parameters is proposed to improve the export transmission limits of the coupled ...
Yuxin Yang +4 more
wiley +1 more source
This study examines how increasing inverter‐based RERs affect fault propagation in MV DNs, ensuring adherence to European grid codes EN 50549‐1 and EN 50549‐2 concerning LVRT requirements. A model predictive current control strategy, an LVRT, and secondary power controllers are developed and tested using a detailed MATLAB/Simulink model of the Sundom ...
Hussain Sarwar Khan +2 more
wiley +1 more source
High Voltage Crossing Strategy of Wind Farm Considering Active and Reactive Coordinated Recovery
ObjectivesTo address the serious high voltage ride-through (HVRT) problem faced by wind farms as a result of the large voltage surge at the grid-connected point after a DC fault, a recovery mechanism of “active priority balancing - reactive power dynamic
MO Jisheng +4 more
doaj +1 more source
An Enhanced Fault Ride‐Through Control Method of the VSG Based on Dynamic Power Compensation
To enhance the fault ride‐through (FRT) capability for the VSGs, an FRT control method based on dynamic power compensation (DPC) is proposed in this article, which comprehensively considers both the fault current limitation and power angle stability for the VSG.
Xueqing Li +5 more
wiley +1 more source
The improved virtual flux–based direct power control (VF‐DPC) strategy for a grid‐connected power converters is proposed in this paper to eliminate current harmonics and mitigate voltage fluctuations during grid voltage faults without using voltage sensors.
Kamel Sayahi +4 more
wiley +1 more source