Results 11 to 20 of about 2,760 (255)

Implementation Strategy of Test Facility Based on Auto-Transformer for LVRT/HVRT Evaluation of Large-Scale Wind Turbine

open access: yesEnergies, 2023
In accordance with South Korea’s recent 2030 Carbon Neutral Plan, an 8GW offshore wind farm is planned for construction in the South-west Sea. Therefore, it is expected that large-scale wind turbines will be installed, and these turbines must operate ...
Byungki Kim   +3 more
doaj   +1 more source

Experimental study on fault ride-through capability of VSC-based HVDC transmission system [PDF]

open access: yesArchives of Electrical Engineering, 2021
For voltage-source-converter based high-voltage-direct-current (VSC-HVDC) transmission systems, fault ride-through (FRT) capability is a very important grid requirement in order to enhance its operational availability under an alternating current (AC ...
Ngo Minh Khoa   +2 more
doaj   +1 more source

Multi-Mode Voltage Sag/Swell Generator Based on Three-Phase Inverter Circuit

open access: yesEnergies, 2021
The voltage ride through capability of the major auxiliary variable-frequency drive (VFD) in large thermal power plants is the key technical issue of power grid and source coordination.
Qiguo Han   +5 more
doaj   +1 more source

Research on the Control Strategy for Voltage Source Doubly-fed Wind Power Converter

open access: yesKongzhi Yu Xinxi Jishu, 2022
At present, the installed capacity of new energy power generation equipment shows a trend of rapid growth. A higher proportion of new energy generation will make the power grid show the characteristics of high impedance, low inertia, weak damping and low
HE Xi   +5 more
doaj   +3 more sources

Development of HVRT and LVRT Control Strategy for PMSG-Based Wind Turbine Generators

open access: yesEnergies, 2020
Various challenges are acknowledged in practical cases with high wind power penetration. Fault ride-through (FRT) capability has become the most dominant grid integration requirements for the wind energy conversion system worldwide. The high voltage ride-
Liang Yuan   +5 more
doaj   +1 more source

Transmission distribution coordination for DER fault ride through support

open access: yesEnergy Reports, 2022
Rapid renewable energy sources (RESs) deployments in transmission and distribution networks have changed power systems’ operation and control mechanisms.
Ha Thi Nguyen   +7 more
doaj   +1 more source

A Novel Control Strategy for AC Fault Ride Through in Multi-terminal DC System

open access: yes发电技术, 2022
This paper proposed a novel control strategy-coordinated DC voltage control (DCVC)-to enhance the AC fault ride through capability of multi-terminal high voltage direct current (HVDC) system.
YANG Zhou   +3 more
doaj   +1 more source

Requirement Analysis of Wind Turbine High Voltage Ride-through Capability Detection and Simulation

open access: yesJournal of Physics: Conference Series, 2022
Abstract With the number of wind farms connected to the power system increasing rapidly, the impact of wind power generation system on power grid system stability is becoming increasingly prominent. Especially when the power grid has transient fault, there will be problems such as reverse power flow, large-area power failure of wind farm
Kunpeng Lu   +8 more
openaire   +1 more source

Flexiable Fault Ride Through Capability Improvement of Semi-Direct Drive Wind Power System Based on Improved Grid-Side Control Strategy

open access: yes南方能源建设, 2023
[Introduction] In order to improve the flexible fault ride through (FFRT) capability of semi-direct drive wind power system, this paper proposes an improved grid-side control strategy with reactive power priority.
Jiangtao GUO, Shuo CHEN, Liling HUANG
doaj   +1 more source

MPC-based DC-link voltage control for enhanced high-voltage ride-through of offshore DFIG wind turbine

open access: yesInternational Journal of Electrical Power & Energy Systems, 2021
Abstract To deal with the DC-link overvoltage during high-voltage ride-through (HVRT) of the wind turbine, a coordinated DC-link voltage control (CDVC) scheme is proposed for enhancing the HVRT performance of offshore doubly-fed induction generator (DFIG) wind turbines equipped with the supercapacitor energy storage system (SESS).
Wei, Juan   +5 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy