Requirement Analysis of Wind Turbine High Voltage Ride-through Capability Detection and Simulation
Abstract With the number of wind farms connected to the power system increasing rapidly, the impact of wind power generation system on power grid system stability is becoming increasingly prominent. Especially when the power grid has transient fault, there will be problems such as reverse power flow, large-area power failure of wind farm
Kunpeng Lu +8 more
openaire +1 more source
A New Fast Peak Current Controller for Transient Voltage Faults for Power Converters [PDF]
Power converters are the basic unit for the transient voltage fault ride through capability for most renewable distributed generators (DGs). When a transient fault happens, the grid voltage will drop suddenly and probably will also suffer a phase-jump ...
Carrasco Solís, Juan Manuel +3 more
core +5 more sources
Modular multilevel converter with modified half-bridge submodule and arm filter for dc transmission systems with DC fault blocking capability [PDF]
Although a modular multilevel converter (MMC) is universally accepted as a suitable converter topology for the high voltage dc transmission systems, its dc fault ride performance requires substantial improvement in order to be used in critical ...
Abdelsalam, Ibrahim A. +3 more
core +2 more sources
[Introduction] In order to improve the flexible fault ride through (FFRT) capability of semi-direct drive wind power system, this paper proposes an improved grid-side control strategy with reactive power priority.
Jiangtao GUO, Shuo CHEN, Liling HUANG
doaj +1 more source
Zero phase sequence voltage injection for the alternate arm converter [PDF]
The Alternate Arm Converter (AAC) is a voltage source converter being developed as an alternative to the Modular Multilevel Converter (MMC) for HVDC power transmission and reactive power compensation.
Dyke, KJ +4 more
core +1 more source
Power dispatch and voltage control in multiterminal HVDC systems : a flexible approach [PDF]
This paper deals with the power dispatch and direct voltage control in multiterminal high voltage direct current (MT-HVDC) systems. Generalized voltage droop (GVD) control is adopted for voltage source converters (VSC)s of a MT-HVDC system.
Dianguo, Xu +6 more
core +1 more source
A high proportion of new energy sources are connected to the grid, which not only alleviates the energy shortage, but also brings hidden dangers to the safe and stable operation of the grid. Aiming at the inadequate consideration of uncertainty caused by
Yuhong Zhu +5 more
doaj +1 more source
Safety Voltage Control Strategy for High Voltage Ride-Through of Doubly Fed Induction Generator (DFIG) [PDF]
a DFIG high voltage ride-through method with the consideration for the safe operation voltage of the generator unit is proposed in the article. Based on the dynamic reactive support capability of DFIG, during grid voltage swell, the reactive powers outputted by the grid-side converter and the generator stator are concertedly controlled so as to keep ...
openaire +1 more source
Power Quality Improvement and Low Voltage Ride through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer [PDF]
© 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission.This paper proposes the application of a dynamic voltage restorer (DVR) to ...
Allaoui, Tayeb +3 more
core +2 more sources
Analysis of Transient Voltage-Frequency Dynamic Coupling Mechanism of High-Proportion Renewable Energy Sending End System Under Commutation Failure Faults [PDF]
[Objective] Aiming at the new challenge of unclear transient voltage and system frequency operation risks faced by sending-end power systems with a high proportion of renewable energy after commutation failure, this paper reveals the dynamic coupling ...
GAO Shang, YIN Chunya, LIU Wan, LI Xiaozhu, HAN Lu, ZHANG Gaohang
doaj +1 more source