Results 261 to 270 of about 37,230 (297)
Some of the next articles are maybe not open access.

Hybrid high-power rectifier with reduced THDI and voltage sag ride-through capability

2011 IEEE Industry Applications Society Annual Meeting, 2011
Temporary voltage sags are the main cause of untimely arrest in automated systems that use adjustable speed drives (ASDs). In this context, this paper presents an analysis of a new hybrid three-phase rectifier designed to correct the power factor and to promote voltage sag ride-through capability to ASDs.
Admarco V. Costa   +5 more
openaire   +1 more source

A coordinated control strategy of DFIG-based WECS for high voltage ride-through enhancement

2014 17th International Conference on Electrical Machines and Systems (ICEMS), 2014
This paper presents an analysis and operation of a Doubly Fed Induction Generator (DFIG)-based wind energy conversion system (WECS) under voltage swell condition. By taking into account both converters' current ratings, a coordinated control scheme of the Grid Side Converter (GSC) and Rotor Side Converter (RSC), with dynamic reactive power supporting ...
Yang Fang, Dan Sun, Pinghua Xiong
openaire   +1 more source

IMC robust control for high‐voltage ride‐through of doubly fed induction wind generator

IEEJ Transactions on Electrical and Electronic Engineering, 2018
To solve system parameter variation such as magnetic circuit saturation and excitation inductance of the doubly fed induction generator (DFIG) caused by grid voltage swells, a high‐voltage ride‐through (HVRT) robust control method for the DFIG based on the internal model control (IMC) controller is proposed.
Xiaoyang Ma, Honggeng Yang
openaire   +1 more source

High voltage ride-through control strategy of grid-side converter for DFIG-based WECS

IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society, 2013
For doubly-fed induction generator (DFIG)-based wind energy conversion system (WECS), grid voltage swell is harmful to the dc-link capacitor and the grid-side converter (GSC). The grid over-voltage may lead to the reversal of power flow in the GSC, resulting in the uncontrollability of the GSC. In order to handle this situation, the control strategy of
Zhong Zheng, Geng Yang, Hua Geng
openaire   +1 more source

Test System Design of Low Voltage Ride Through of High Altitude Photovoltaic Power Station

2018 China International Conference on Electricity Distribution (CICED), 2018
the photovoltaic resources are abundant in the high altitude area of northwest China, but the network frame is weak in this kind of area, and it is urgent to carry out the detection of Photovoltaic grid connected network test. It is necessary to solve the problem of system insulation safety with Low Voltage Ride Through (LVRT) test for photovoltaic ...
Wang Deshun   +4 more
openaire   +1 more source

Application of SMES unit to improve the high-voltage-ride-through capability of DFIG-grid connected during voltage swell

2011 IEEE PES Innovative Smart Grid Technologies, 2011
The amount of wind turbine connected to the power grid has significantly increased during the last decade. This has resulted in essential need to establish grid codes. Previously, wind turbine generators (WTGs) were allowed to be disconnected from the network during any disturbance at the grid side to avoid WTGs from being damaged. However, lately, the
A. M. Shiddiq Yunus   +2 more
openaire   +1 more source

High voltage ride-through of grid-side converter for PMSG based directly driven wind turbines

2016 35th Chinese Control Conference (CCC), 2016
Permanent-magnet synchronous generator (PMSG) based directly driven wind turbine is connected to grid through the grid-side converter (GSC), grid voltage swell fault directly affects the operation of grid-side converter. In this paper, the analysis of the voltage and current constraints of the GSC under grid voltage swell is given firstly, and then a ...
Changxian Liu, Jing He, Zhen Xie
openaire   +1 more source

Improvement of High-Voltage-Ride-Through Capability of DFIG Based Wind Turbines with D-STATCOM

Applied Mechanics and Materials, 2013
Along with the increasing of wind power penetration in the grid, much attention has been paid to the high voltage ride through (HVRT) capability of double fed induction generator (DFIG) based wind parks. To regulate the reactive power dynamically, the distribution static synchronous compensator (D-STATCOM) has been considered to be a valid method.
Guo Qing Li, Rui Feng Zheng, Hou He Chen
openaire   +1 more source

Low Voltage Ride-Through of high power DFIG wind turbine using three-level NPC converters

2009 35th Annual Conference of IEEE Industrial Electronics, 2009
Nowadays, there is a tendency to increase the power of wind turbines. Multilevel converter is a realistic alternative in such high power applications. As the most widely used variably speed wind turbine, doubly fed induction generators (DFIG) are very sensitive to grid disturbances.
Ling Peng, Bruno Francois, Yongdong Li
openaire   +1 more source

Application of STATCOM to improve the high-voltage-ride-through capability of wind turbine generator

2011 IEEE PES Innovative Smart Grid Technologies, 2011
Variable speed wind turbine with full scale converter or so-called type-D wind turbine generator worldwide installation has been significantly increased in the last few years. Voltage Swell in the grid side may cause the wind turbine to be disconnected from the grid.
Y. M. Alharbi   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy