Improving the Electricity Quality by Means of a Single-Phase Solid-State Transformer
The paper describes the use of a single-phase three-stage solid-state transformer in networks with non-sinusoidal voltages in order to improve the quality of electricity. An active-inductive load was chosen as the load.
Boris Avdeev +2 more
doaj +1 more source
Finding, and Not Finding, “Higher Harmonic Flows” [PDF]
Certain analysis methods have emerged recently that claim to reveal "higher harmonic flows" in more-central åcollisions at the RHIC and LHC. But pQCD calculations describe the same structures quantitatively.
openaire +2 more sources
In industrial plants with dynamically varying load profiles, the problem of increased charges for over-contracted reactive power consumption is very common. To eliminate these charges, reactive power compensation systems are used. This article presents a
Marian Hyla, Andrzej Latko
doaj +1 more source
The twisted higher harmonic signature for foliations
We prove that the higher harmonic signature of an even dimensional oriented Riemannian foliation of a compact Riemannian manifold with coefficients in a leafwise U(p,q)-flat complex bundle is a leafwise homotopy invariant. We also prove the leafwise homotopy invariance of the twisted higher Betti classes.
Benameur, Moulay-Tahar +1 more
openaire +3 more sources
Determination of higher harmonics source in mixed-load power supply systems
The article considers the possibility of determining the source of higher harmonics of currents and voltages in the electrical network in the directions of power of the respective components.
Dmytro Gapon +3 more
doaj +1 more source
Nowadays permanent magnet synchronous machines those frequency-controlled from stator side with frequency inverters made on the basis of power transistors or fully controlled thyristors, are widely used as motors and generators.
Hasanova L. H. , Mustafayev R. I.
doaj +1 more source
Development of Inductive Current Transformer 400/5/1 of Class 0.2S for Frequency Range 50 Hz–5 kHz
This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process
Michal Kaczmarek, Blazej Pacholczyk
doaj +1 more source
The novelty of the paper contributes to the increase of the reliability of the methods used for evaluation of the inductive CTs accuracy of transformation of the distorted current.
Michal Kaczmarek, Ernest Stano
doaj +1 more source
According to standards, the harmonic content should be less than 5% at the time of calibration, while the calibration index proposed in this paper stipulates that the primary current amplitude of 1%~120% of the full range of the accuracy level reaches 0 ...
Can Ding +3 more
doaj +1 more source
We developed an impedance quartz crystal microbalance (QCM) approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer.
Manuel Kasper +5 more