Results 61 to 70 of about 3,260 (186)
The Graphical Abstract depicts the proposed Artificial Bee Colony algorithm‐based optimal tuning of PI controllers for back‐to‐back Voltage Source Converters in a hybrid wind–PV system. ABSTRACT This paper proposes a hybrid model‐based back‐to‐back voltage‐source converter (B2B‐VSC) system comprising a Photovoltaic (PV) array and a Permanent Magnet ...
Ch. Sreenu +3 more
wiley +1 more source
Research of optimized sorting algorithm of capacitor voltage for MMC
The paper researched primary cause of increasing of switching frequency of modular multilevel converter led by traditional capacitor voltage sorting algorithm according to operation principle of the converter. It proposed an improved sorting algorithm of
SONG Pinggang +3 more
doaj +1 more source
Dynamic Covalent Chemistry Enables Self‐Healing and Compatibilization in Polypropylene Composites
A high‐performance polypropylene insulation material is created through dynamic covalent crosslinking. It achieves exceptional dielectric properties, autonomous self‐healing, and easy recycling, offering a sustainable solution for future HVDC transmission systems.
Hongzhe Zhang +3 more
wiley +1 more source
Design and Application of an Intelligent Monitoring System in HVDC Valve Hall
[Introduction] To overcome some shortcoming such as labor-intensity and inefficient-inspection in manual inspection, which is commonly adopted in the maintenance of the equipment in a HVDC valve hall, a intelligent monitoring system could be established.
LIU Yanhua +3 more
doaj +1 more source
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali +6 more
wiley +1 more source
The widespread integration of photovoltaics (PVs) presents significant challenges to the operation and control of distribution systems, particularly in maintaining voltage stability at nodes with PV connections.
Baoye Tian +7 more
doaj +1 more source
During regular operation of the SuedLink at a load ≤75 %, the average increase in temperature in the plowing horizon is expected to be less than 1.6°C in the soils along the route in Southwest Germany. ABSTRACT Background The SuedLink was planned as a high‐voltage direct‐current underground cable route. The construction itself is a massive intervention
Joachim Ingwersen +10 more
wiley +1 more source
Hybrid Filters To Damp Harmonic Resonance In Power Transmission Systems
Problems related to harmonic propagation in transmission systems have been noticed in the last years. Passive filters, commonly used to attenuate noncharacteristic harmonics in HVDC systems, stay at risk of disconnection from the system due to ...
Lucas F. Encarnação +4 more
doaj +1 more source
Noise Characteristics of ±800 kV HVDC Convert StationBased on Spectrum Analysis
By collecting the sound pressure signals of the aerodynamic noise of the converter transformer fans, the electric field noise of the smoothing reactors and the electric field noise of the DC/ AC filter field in the 800 kV converter station, the spectrum ...
Yu HAN, Chao FAN, Guangke WANG, Qiang HE
doaj +1 more source
HAPF (high voltage active power filter) and SVG (static var generator), which are specially used for filtering in large-capacity HVDC projects, are configured in the Min-Yue back-to-back HVDC transmission project to meet the filtering requirements and ...
Xiao LEI +4 more
doaj +1 more source