Results 71 to 80 of about 17,685 (234)
The widespread integration of photovoltaics (PVs) presents significant challenges to the operation and control of distribution systems, particularly in maintaining voltage stability at nodes with PV connections.
Baoye Tian +7 more
doaj +1 more source
Deterioration Law of Mechanical Properties of Insulation Pressboard Under Multifield Coupled Ageing
ABSTRACT Converter transformers can experience progressive deterioration of their oil–pressboard insulation under elevated temperature, combined AC–DC electrical stress and persistent mechanical vibration. This study investigates how mechanical vibration affects the mechanical properties of insulation pressboard and clarifies the associated microscopic
Jiayi Chen +5 more
wiley +1 more source
The best commercial high-voltage insulation material of today is (crosslinked) ultra-pure low-density polyethylene (LDPE). A 100-fold decrease in electrical conductivity can be achieved by adding 1−3 wt.% of well-dispersed inorganic nanoparticles ...
Shima L. Holder +4 more
doaj +1 more source
control-protection-grids-tudelft/HVDC-RTDS-models: HVDC_models
<p>HVDC/AC models with the European ratings.</p ...
HVDC/AC Control, Aleksandra Lekić, Ajay
core +1 more source
MMC Stored Energy Participation to the DC Bus Voltage Control in an HVDC Link [PDF]
The modular multilevel converter (MMC) is becoming a promising converter technology for HVDC transmission systems. Contrary to the conventional two- or three-level VSC-HVDC links, no capacitors are connected directly on the dc bus in an MMC-HVDC link ...
SAMIMI, Shabab +5 more
core +1 more source
The interest in half-bridge Voltage Source Converters (VSCs) with HVDC circuit breakers is a solution to manage transient faults when the link is fully or partially made with an overhead line.
Patti, S. +6 more
core +1 more source
ABSTRACT The problem of gas–solid interface charge accumulation is an important reason for distorting the surface electric field and then inducing surface discharge. The temperature gradient distribution formed on the spacer during the operation of a gas‐insulated transmission line (GIL) will aggravate the surface charge accumulation, further ...
Jianyi Xue +6 more
wiley +1 more source
Black-start of remote areas through SCR-based HVDC Links
This paper analyses the possibility to black-start a remote area using an existing Line Commutated Converter HVDC link.To do this, a relatively small size Voltage Sourced Converter must be installed at the link receiving-end.
Sani L. +7 more
core +1 more source
ABSTRACT The stability analysis of Line Commutated Converter High Voltage Direct Current (LCC‐HVDC) is of considerable engineering importance. Establishing its analytical mathematical model helps to analyse stability and the factors that affect stability of the system.
Juanjuan Wang +6 more
wiley +1 more source
ABSTRACT The long‐term hydrophobic stability of silicone rubber (SiR) insulators is essential for their reliability in high‐voltage direct current (HVDC) applications. This study investigates the effect of nano‐silica fillers with varying specific surface areas (SSA = 120, 200 and 300 m2/g) and different concentrations of alumina trihydrate (ATH ...
Mahmoud A. Ali +3 more
wiley +1 more source