A low-cost current flow controlling interline hybrid circuit breaker combined with SCR and H-bridge sub-module

open access: yesFrontiers in Energy Research, 2023
A massive number of DC circuit breaker is usually necessary to be installed to protect HVDC grids from DC faults, this will lead to high capital costs because large number of expensive IGBT-in-series are used.
Qingpeng Zeng   +9 more
doaj   +1 more source

Review of different fault detection methods and their impact on pre-emptive VSC-HVDC dc protection performance

open access: yesHigh Voltage, 2017
Multi-terminal voltage-sourced converters (VSC) high-voltage direct current (HVDC) transmission system is expected to play a vital role in future power systems.
Bin Chang   +6 more
doaj   +1 more source

Research on Overvoltage Suppression by Blocking Diode and DC Circuit Breaker in LCC-VSC Hybrid HVDC System

open access: yesIEEE Access, 2021
In this study, a LCC-VSC hybrid HVDC transmission system was taken as an example. The valve and neutral overvoltage of the hybrid HVDC system were simulated and then calculated at the VSC converter station by installing a blocking diode and a DC circuit ...
Wang Dongju, Zhou Hao
doaj   +1 more source

Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker

open access: yesZhongguo dianli, 2021
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN   +4 more
doaj   +1 more source

Integrated HVDC Circuit Breakers With Current Flow Control Capability [PDF]

open access: yesIEEE Transactions on Power Delivery, 2018
Two key problems in meshed high-voltage direct current (HVDC) transmission grids are managing line power flows and protection against dc faults. Current flow controllers (CFCs) will be required to balance cable currents in meshed dc grids, in order to prevent individual line power capacity limits restricting overall power flow in the grid.
Cwikowski, Oliver   +6 more
openaire   +5 more sources

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +7 more
core   +1 more source

Reduced DC circuit breaker requirement on mixed converter HVDC networks [PDF]

open access: yes, 2015
Recently proposed meshed HVDC networks include both converters and DC circuit breakers, and the fault currents experienced and therefore the capacity requirement of circuit breakers are dependent on the topology of converters used on the network.
Green, TC   +3 more
core   +1 more source

Converter for Voltage Source HVDC Links: Current Status and Future Challenges

open access: yesEdison Journal for Electrical and Electronics Engineering, 2023
This article discusses the current state of DC HVDC technology. The article describes the history of DC HVDC technology, starting with its early development as a voltage source, and then discusses the introduction of line-cutting into current designs ...
Atheer Ahmed Kadhim   +2 more
doaj   +1 more source

4-Pole Hybrid HVDC Circuit Breaker for Pole-to-Pole (PTP) Fault Protection

open access: yesIEEE Access, 2022
Numerous problems have emerged with the development of HVDC transmission technology. One of them is the fault current that occurs when there is an issue in the line. In particular, in the case of a PTP (pole-to-pole) fault, a DCCB design suitable for the
Geon Kim   +7 more
doaj   +1 more source

Research on the Modification Plan of HVDC Transfer Switch Arrester

open access: yes南方能源建设, 2022
[Introduction] During the earth return and metallic return mode conversion of China's HVDC transmission projects in operation, several MRTB (metallic return transfer breaker) or ERTB (earth return transfer breaker) oscillation platform arrester damage ...