Results 41 to 50 of about 3,375 (209)

Circuit Breaker Failure Protection Strategy for HVDC Grids

open access: yesEnergies, 2021
HVDC grids demand the fast and reliable operation of the protection system. The failure of any protection element should initialize a backup protection almost immediately in order to assure the system’s stability.
María José Pérez-Molina   +3 more
doaj   +1 more source

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +3 more
core   +1 more source

Systematic Approach to HVDC Circuit Breaker Sizing [PDF]

open access: yesIEEE Transactions on Power Delivery, 2020
High-voltage direct current (HVDC) grids can be protected by HVDC circuit breakers (DCCB) to selectively clear DC side faults and assure continuous operation of the healthy parts in the grid. Line inductors in series with DCCBs are essential to reduce the rate of rise of the fault current and to slow down the voltage decline in the healthy parts of the
Abedrabbo, Mudar   +2 more
openaire   +1 more source

Modular Reciprocating HVDC Circuit Breaker with Current-limiting and Bi-directional Series-parallel Branch Switching Capability

open access: yesJournal of Modern Power Systems and Clean Energy, 2020
The high-voltage direct current (HVDC) circuit breaker is becoming popular with the rapid development of the flexible HVDC grid for efficient DC fault ride-through purposes.
Jianzhong Xu, Moke Feng, Chengyong Zhao
doaj   +1 more source

A low-cost current flow controlling interline hybrid circuit breaker combined with SCR and H-bridge sub-module

open access: yesFrontiers in Energy Research, 2023
A massive number of DC circuit breaker is usually necessary to be installed to protect HVDC grids from DC faults, this will lead to high capital costs because large number of expensive IGBT-in-series are used.
Qingpeng Zeng   +9 more
doaj   +1 more source

Review of different fault detection methods and their impact on pre-emptive VSC-HVDC dc protection performance

open access: yesHigh Voltage, 2017
Multi-terminal voltage-sourced converters (VSC) high-voltage direct current (HVDC) transmission system is expected to play a vital role in future power systems.
Bin Chang   +6 more
doaj   +1 more source

Research on Overvoltage Suppression by Blocking Diode and DC Circuit Breaker in LCC-VSC Hybrid HVDC System

open access: yesIEEE Access, 2021
In this study, a LCC-VSC hybrid HVDC transmission system was taken as an example. The valve and neutral overvoltage of the hybrid HVDC system were simulated and then calculated at the VSC converter station by installing a blocking diode and a DC circuit ...
Wang Dongju, Zhou Hao
doaj   +1 more source

DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application [PDF]

open access: yes, 2015
Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges ...
Aboushady, Ahmed A.   +2 more
core   +2 more sources

Modified half-bridge modular multilevel converter for HVDC systems with DC fault ride-through capability [PDF]

open access: yes, 2014
One of the main challenges of voltage source converter based HVDC systems is DC faults. In this paper, two different modified half-bridge modular multilevel converter topologies are proposed.
Aboushady, A.A., Ahmed, K.H.
core   +2 more sources

Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker

open access: yesZhongguo dianli, 2021
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN   +4 more
doaj   +1 more source