Results 21 to 30 of about 8,461 (290)

Parameters design of voltage sharing components for the series multi‐break mechanical switch

open access: yesIET Science, Measurement & Technology, 2022
Series multi‐break mechanical switch is one of the critical components of high‐voltage hybrid DC circuit breakers. However, due to the existence of distributed capacitance, the voltage distribution between the breaks is not balanced.
Daochun Huang   +5 more
doaj   +1 more source

Development and Application of a 10 kV Mechanical DC Circuit Breaker

open access: yesEnergies, 2019
A DC circuit breaker is piece of core equipment for DC grid construction and can achieve fast isolation of DC faults in the grid. In this paper, based on the fault characteristics and protection requirements of an AC/DC hybrid distribution network, the ...
Lu Qu   +5 more
doaj   +1 more source

DC/DC converters based on hybrid MMC for HVDC grid interconnection [PDF]

open access: yes, 2015
This paper presents a multi-terminal high-power DC/DC converter configuration based on hybrid MMC topology with fault blocking capability for interconnecting HVDC systems.
Xu, Lie, Yao, Liangzhong, Zeng, Rong
core   +1 more source

Research on topological structure and simulation of hybrid DC circuit breaker

open access: yesThe Journal of Engineering, 2019
At present, the hybrid DC circuit breaker (ABB company's Hybrid DC circuit breaker as the representative scheme) must be equipped with the radiator because of a long-time current passing through the power electronic devices in the load-control-switch ...
Chu Zhuang   +3 more
doaj   +1 more source

A Current-Commutation DC Circuit Breaker with Adaptive Reclosing Capability [PDF]

open access: yesE3S Web of Conferences, 2021
DC faults are critical events in a flexible high-voltage dc (HVDC) grid. Thus, ensuring that the power system returns to normal operation rapidly and reliably after fault isolation is very important. This requires a HVDC breaker. In overhead line systems
Jiang Chunbing, Zhao Chengyong
doaj   +1 more source

Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]

open access: yes, 2014
Peer ...
Jovcic, Dragan   +3 more
core   +1 more source

Current Limiting Hybrid High Voltage DC Circuit Breaker With Reclosing Function Limiting

open access: yesJournal of Applied Science and Engineering, 2022
DC circuit breaker is the core equipment for the safe operation of DC transmission system. A current limiting hybrid HVDC circuit breaker topology with reclosing function is proposed in this paper.
Baoge Zhang   +4 more
doaj   +1 more source

Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]

open access: yes, 2017
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X   +6 more
core   +1 more source

A hybrid circuit breaker based on current commutation approach for multi-feeder DC railway substations

open access: yesCSEE Journal of Power and Energy Systems, 2019
The paper presents an economic hybrid circuit breaker for limiting and interrupting the faults in DC railways substations. For fast fault current interruption, the hybrid breaker incorporates high speed mechanical contacts actuated by power semiconductor
Saady Hasan
doaj   +1 more source

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +3 more
core   +1 more source