Lone‐Pair‐Induced Lattice Distortion in Lead‐Free Hybrid Perovskites for High‐Performance Nanogenerators

open access: yesAdvanced Functional Materials, EarlyView.
A lead‐free tin‐based hybrid perovskite is designed in which stereochemically active lone‐pair electrons on tin distort the crystal lattice and break its symmetry. Blended into a flexible polymer, the material converts pressure into electricity at milliwatt‐scale power density and continues working far below freezing, powering a commercial wristwatch ...
Majid Haji Bagheri   +12 more
wiley   +1 more source

A low-cost current flow controlling interline hybrid circuit breaker combined with SCR and H-bridge sub-module

open access: yesFrontiers in Energy Research, 2023
A massive number of DC circuit breaker is usually necessary to be installed to protect HVDC grids from DC faults, this will lead to high capital costs because large number of expensive IGBT-in-series are used.
Qingpeng Zeng   +9 more
doaj   +1 more source

Efficient Magnetization Switching Driven by Orbital Torque in Light 3d Transition‐Metal Nitrides

open access: yesAdvanced Functional Materials, EarlyView.
Efficient magnetization switching is demonstrated through orbital torque generated from light 3d transition‐metal nitride. Transition‐metal nitrides are established as effective sources of orbital angular momentum for current‐induced switching, highlighting their potential for low‐power next‐generation orbitronic devices beyond conventional heavy‐metal‐
Gaurav K. Shukla   +3 more
wiley   +1 more source

Investigations on the safe stroke of mechanical HVDC vacuum circuit breaker

open access: yesThe Journal of Engineering, 2019
Here, a DC vacuum arc interruption test based on the hybrid high-speed actuator and the method of commutation is carried out in the synthetic loop system. The safe stroke is one of the basic breaking parameters.
Ning Xia   +5 more
doaj   +1 more source

The DC circuit-breaker for low-voltage grids : design, implementation and analysis of DC circuit-breaker with countercurrent injection principle

open access: yes, 2021
Faults in DC systems are difficult to interrupt compared to their AC counterparts due to absence of natural current-zero (CZ) crossing in DC current. This puts forward the need of enhanced arc chambers inside the circuit-breaker to cope with DC arc.
Virdag, Muhammad-Ali-Khan
core   +1 more source

Digitally Printed Eco‐Friendly Electronic Devices

open access: yesAdvanced Functional Materials, EarlyView.
Fabrication of electronics using eco‐friendly materials through digital printing routes is a promising strategy for improving life cycle sustainability and reducing the environmental impacts of conventional manufacturing. This review highlights state‐of‐the‐art eco‐friendly materials, green ink formulations, various resource‐efficient digital printing ...
Nitheesh M. Nair   +5 more
wiley   +1 more source

Design and Experimental Tests of a Superconducting Hybrid DC Circuit Breaker [PDF]

open access: yes, 2018
Direct current (DC) circuit breakers are a key ena-bling technology for fault management in multi-terminal high voltage direct current (HVDC) systems. DC fault isolation is chal-lenging due to the high rate of rise of the fault current and the lack of ...
Oliver Cwikowski   +11 more
core   +1 more source

Biodegradable Conductors for Implantable and Wearable Transient Bioelectronics

open access: yesAdvanced Functional Materials, EarlyView.
Biodegradable conductors are essential building blocks for transient bioelectronics, enabling temporary sensing, stimulation, and energy transfer while eliminating the need for device retrieval. This review summarizes biodegradable metals, conducting polymers, ionic conductors, and conductive composites, highlighting degradation mechanisms, material ...
Yicheng Zhu, Yijun Liu, Naoji Matsuhisa
wiley   +1 more source

Auxiliary Branch for Hybrid DC Circuit Breaker in Flexible DC Grid to Reduce Fault Breaking Time and Arrester Capacity Demand

open access: yesIEEE Access
Considering the voltage source characteristics of the converters in the flexible DC grid, the current-limiting reactors are usually placed on the DC line terminals to limit the fault current rising speed.
Yingqing Ma   +5 more
doaj   +1 more source

Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker

open access: yesZhongguo dianli, 2021
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN   +4 more
doaj   +1 more source