Results 41 to 50 of about 66,094 (288)

Phantom reference image

open access: yes, 2020
A proton density weighted phantom ...
, Bruno, , Burak, , Pierre, Juergen
openaire   +2 more sources

Digital mouse phantom for optical imaging

open access: yesJournal of Biomedical Optics, 2007
We present a method for design and use of a digital mouse phantom for small animal optical imaging. We map the boundary of a mouse model from magnetic resonance imaging (MRI) data through image processing algorithms and discretize the geometry by a finite element (FE) descriptor.
Shekhar, Dwivedi   +2 more
openaire   +2 more sources

Reproducibility of 3D-Printed Breast Phantoms in Mammography and Breast Tomosynthesis

open access: yesTechnologies
The development of realistic breast phantoms is critical for the evaluation of imaging systems and quantitative image analysis methods. In this work, breast samples derived from the same digital model were produced using 3D printing technology and ...
Kristina Bliznakova   +8 more
doaj   +1 more source

Clinical and Biological Features of Response in Resistant Neuroblastoma to 131I‐Metaiodobenzylguanidine Radiotherapy in the Anti‐GD2 Immunotherapy Era

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background 131I‐metaiodobenzylguanidine (131I‐MIBG) radiotherapy is a key treatment for relapsed and refractory (R/R) neuroblastoma (NB). Patients with R/R disease treated in the modern era are increasingly exposed to anti‐GD2 immunotherapy, which exerts selective pressure and may modify both tumor cell state and microenvironment.
Benjamin J. Lerman   +7 more
wiley   +1 more source

Rapid and Quantitative Chemical Exchange Saturation Transfer (CEST) Imaging with Magnetic Resonance Fingerprinting (MRF)

open access: yes, 2017
Purpose: To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. Methods: We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the
Cohen, Ouri   +4 more
core   +1 more source

Heterogeneity in the Global Practice of Central Nervous System Staging in Pediatric Acute Lymphoblastic Leukemia

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Central nervous system (CNS) involvement in childhood acute lymphoblastic leukemia (ALL) is assessed by cell counting and cytomorphology from cerebrospinal fluid (CSF) and is used for treatment stratification worldwide. The ratio of “CNS2” patients in clinical trials ranges from 3% to 40%, with unclear prognostic significance ...
Laura Almási   +14 more
wiley   +1 more source

Super phantoms: advanced models for testing medical imaging technologies

open access: yesCommunications Engineering
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue.
Srirang Manohar   +4 more
doaj   +1 more source

High-Resolution Ultrasound-Switchable Fluorescence Imaging in Centimeter-Deep Tissue Phantoms with High Signal-To-Noise Ratio and High Sensitivity via Novel Contrast Agents. [PDF]

open access: yesPLoS ONE, 2016
For many years, investigators have sought after high-resolution fluorescence imaging in centimeter-deep tissue because many interesting in vivo phenomena-such as the presence of immune system cells, tumor angiogenesis, and metastasis-may be located deep ...
Bingbing Cheng   +7 more
doaj   +1 more source

Increased Risk of Sarcomas in Children With Congenital Anomalies: Findings From the Genetic Overlap Between Anomalies and Cancer in Kids (GOBACK) Registry Linkage Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Pediatric sarcomas are a heterogeneous group of tumors that contribute disproportionately to cancer mortality in children. Although congenital anomalies are among the strongest known risk factors for childhood cancer, the risk of specific sarcoma subtypes among affected individuals has not yet been thoroughly evaluated. Procedure We
Russ Wolters   +17 more
wiley   +1 more source

Design of Anisotropic Diffusion Hardware Fiber Phantoms [PDF]

open access: yes, 2009
A gold standard for the validation of diffusion weighted magnetic resonance imaging (DW-MRI) in brain white matter (WM) is essential for clinical purposes but still not available.
Baete, Steven   +3 more
core   +1 more source

Home - About - Disclaimer - Privacy