Results 81 to 90 of about 26,977 (247)
ABSTRACT Introduction Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a potentially life‐threatening arrhythmic disorder typically treated with beta‐blockers and, occasionally, with flecainide. Methods All patients underwent genetic testing, electrocardiogram, echocardiogram, and exercise testing.
Fernando Wangüemert‐Perez +9 more
wiley +1 more source
Smartphone heart monitors in pediatric CIEDs: A pilot study. Smartphone heart monitors did not induce EMI in children with CIEDs, enabling reliable heart rate measurement and accurate identification of ventricular non‐captures. ABSTRACT Background Portable heart monitors enable on‐demand electrocardiogram (ECG) recordings and enhance symptom‐rhythm ...
Chun‐Lok Ho +3 more
wiley +1 more source
Pacemakers and implantable cardioverter defibrillators [PDF]
Summary An increasing number of patients are now treated cardiac pacemakers and implantable cardioverter defibrillators and the technology of these is constantly changing. It is vital to have a good understanding of how they function and what the real risks are.
openaire +2 more sources
ABSTRACT Background In patients with structural heart disease (SHD) and moderately impaired left ventricular ejection fraction (LVEF > 35%), data on outcomes after ventricular tachycardia (VT) ablation remain limited. This analysis focuses on VT recurrence after ablation in patients presenting with sustained VT and LVEF > 35% within a secondary ...
Said‐Elias Waezsada +14 more
wiley +1 more source
ABSTRACT Introduction Patients with repaired tetralogy of Fallot (rTOF) remain at risk of ventricular tachycardia (VT). This risk is most commonly related to slow conduction within the septal isthmus, which is defined as the region between the ventricular septal defect (VSD) patch and adjacent valvular annuli.
Yuki Matsuoka +8 more
wiley +1 more source
Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals
Background Increasing use of cardiac implantable electronic devices (CIEDs) has raised concerns about psychological distress in young adults. We evaluated the risk of incident mental disorders after CIED implantation.
Young‐Hae Go +9 more
doaj +1 more source
Q waves are the strongest electrocardiographic variable associated with primary prophylactic implantable cardioverter-defibrillator benefit: a prospective multicentre study. [PDF]
Pelli A +13 more
europepmc +1 more source
QT Interval Evaluation in Right Ventricular Pacing: Validation of a Novel Formula
Abstract Background QT interval measurement in the presence of right ventricular pacing (RVP) represents a clinical challenge. We therefore aimed to derive and validate a formula for QT estimation during RVP in a large cohort of pacemaker patients. Methods and Results We prospectively enrolled 100 patients in a derivation cohort and 487 in a validation
Amr Abdin +9 more
wiley +1 more source
ABSTRACT Introduction Preprocedural imaging can improve the success rate of ventricular tachycardia (VT) ablation. Left ventricular wall thickness (LVWT) measured by cardiac computed tomography (CT) can be used to identify infarct regions. We sought to determine whether an association exists between left ventricular wall thickness (LVWT) as obtained ...
Alwin B. P. Noordman +4 more
wiley +1 more source
An implantable cardioverter defibrillator in a patient with triple mechanical valves
Key Clinical Message A patient with permanent atrial fibrillation, triple mechanical prosthetic valve replacements, and nonischemic cardiomyopathy presented with symptomatic high‐grade atrioventricular block.
Alex W. X. Tan +3 more
doaj +1 more source