Analysis of Zinc Oxide (ZnO) Surge Arrester Connected to Various Ground Electrodes
This paper presents impulse tests results on a zinc oxide (ZnO) surge arrester connected to four ground electrodes, with its resistance values ranging from 17 Ω to 104 Ω.
Hanis Hamizah Hizamul-Din +1 more
doaj +1 more source
Characteristics of the Flexible Graphite Grounding Material and its Engineering Application
In order to meet the requirements of corrosion resistance of the grounding material and thermal stability of the grounding material of the transmission line towers, under the condition of power frequency current and high-frequency lightning current ...
Daochun Huang +4 more
doaj +1 more source
Ionisation can occur in the soil when high impulse currents are subjected to grounding systems. This occurrence is generated by a difference in the dielectric strength value between the soil and air voids.
Hanis Hamizah Hizamul-Din +3 more
doaj +1 more source
Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo +4 more
core +1 more source
Mechanism Analysis and Multiphysics Validation of Lightning Attenuation in Constrained Space
The problem of resistance reduction has always been the key and difficult point of lightning protection. However, the problem of reducing the grounding resistance efficiently has not been solved. A method is introduced in this paper to solve this problem
Yang Lu +3 more
doaj +1 more source
Analysis of Lightning Transient Characteristics of Short-Length Mixed MMC-MVDC Transmission System
Medium voltage direct current (MVDC) transmission system are growing due to their assistive quality in conventional grid and compatibility with renewable power network. MVDC distribution links with “Mixed” overhead (OH) & underground
Muhammad Usman +2 more
doaj +1 more source
Optimization of impulse resistance reduction for tower grounding device of transmission line
Abstract When the lightning strikes the tower, the lightning current is discharged into the ground through the tower grounding device. The magnitude of the impulse earthed resistance of the tower grounding device determines the lightning discharge capacity of the tower. Therefore, the tower grounding device directly affects the lightning
Sixiang Chen +5 more
openaire +1 more source
Interests without History: Some Difficulties for a Negative Aristotelianism [PDF]
This paper focuses on 3 features of Freyenhagen's Aristotelian version of Adorno. (a) It challenges the strict negativism Freyenhagen finds in Adorno. If we have morally relevant interests in ourselves, it is implicit that we have a standard by which to ...
Adorno, Adorno, Hegel
core +1 more source
A New Flexible Graphite Composite Electrical Grounding Material
Corrosion is an inevitable problem of metallic grounding grids. To propose an effective method avoiding the above corrosion, a new type of non-metallic grounding material was made in this paper. It is called flexible graphite composite grounding material,
Tao Huang +7 more
doaj +1 more source
Ground Potential Rise and Transient Response of the Grounding Grid Based on the Triggered Lightning
It is extremely dangerous of ground grid potentials which significantly rise when the lightning currents are flowing through the grid. A statistical analysis on 39 return-strokes, 10 M-components and the ground potential rise (GPR) caused by them based ...
Yan Xu +4 more
doaj +1 more source