Results 41 to 50 of about 2,085,793 (277)

Impact of external interfering factors on the accuracy of static and impulse resistance measurement of grounding [PDF]

open access: yes, 2007
Podstawowym parametrem charakteryzującym skuteczność działania uziemienia jest jego rezystancja. Dla uziemień odgromowych powinna ona być wyznaczana przy wymuszeniu udarowym zaś dla uziemień ochronnych i roboczych przy częstotliwościach bliskich ...
Wołoszyk, M.
core  

A Novel Drug‐Loaded Porous Parylene Electrode for Targeted Anti‐Inflammatory Therapy and Hearing Preservation in Cochlear Implantation

open access: yesAdvanced Healthcare Materials, EarlyView.
A porous parylene‐coated electrode loaded with dexamethasone was developed to reduce inflammation after cochlear implantation. In guinea pigs, the device provided sustained drug release, maintained biocompatibility, improved auditory brainstem response thresholds, and reduced inflammatory cell infiltration and TNF‐α expression.
Chi‐Chieh Chang   +11 more
wiley   +1 more source

A grounding method of OCS pillar foundation based on conductive concrete

open access: yes机车电传动, 2023
A grounding method of OCS pillar foundation based on conductive concrete was proposed to solve the grounding problem of traction power supply system in areas with high soil resistivity. The proportioning of materials for conductive concrete was optimized
CHANG Zhanning   +5 more
doaj  

Making the Case for Organ‐on‐Chip Platforms in Long‐Acting Therapeutics Development

open access: yesAdvanced Healthcare Materials, EarlyView.
LATs release drug from a tissue‐resident depot over weeks to months, improving adherence, but their development is hampered by preclinical models that cannot reproduce the coupled tissue processes, sustained release, local microenvironment change, interstitial transport, immune and foreign‐body responses, and clearance that govern depot performance in ...
Charlie Gowans   +7 more
wiley   +1 more source

Beyond Presumptions: Toward Mechanistic Clarity in Metal‐Free Carbon Catalysts for Electrochemical H2O2 Production via Data Science

open access: yesAdvanced Materials, EarlyView.
Metal‐free carbon catalysts enable the sustainable synthesis of hydrogen peroxide via two‐electron oxygen reduction; however, active site complexity continues to hinder reliable interpretation. This review critiques correlation‐based approaches and highlights the importance of orthogonal experimental designs, standardized catalyst passports ...
Dayu Zhu   +3 more
wiley   +1 more source

Study on lightning protection scheme of multi-terminal MMC-MVDC distribution system

open access: yesHigh Voltage, 2020
Based on a ±10 kV three-terminal MMC-MVDC (medium voltage DC distribution system based on modular multilevel converter) system, in this study, the authors mainly study on the influencing factors and protection schemes of the lightning intruding ...
Yuqun Gao   +7 more
doaj   +1 more source

A novel approach for grounding resistance estimation [PDF]

open access: yes, 2022
Grounding is crucial to achieving equipment and personnel protection. This paper presents input-output pair-based modeling using the response surface method and artificial neural network to predict earth resistance for novel factors associated with ...
Karandikar, Parashuram B.   +7 more
core   +1 more source

Topology and Material Optimization in Ultra‐Soft Magneto‐Active Structures: Making Advantage of Residual Anisotropies

open access: yesAdvanced Materials, EarlyView.
Residual magnetization induces pronounced mechanical anisotropy in ultra‐soft magnetorheological elastomers, shaping deformation and actuation even without external magnetic fields. This study introduces a computational‐experimental framework integrating magneto‐mechanical coupling into topology optimization for designing soft magnetic actuators with ...
Carlos Perez‐Garcia   +3 more
wiley   +1 more source

A Geometrically Transient Platform for Bioelectronic Implants

open access: yesAdvanced Materials, EarlyView.
Minimally invasive bioelectronic implants often compromise performance for smaller sizes. To resolve this optimization dilemma, a wireless bioelectronic implant with a transient geometry is introduced (MiFi). The origami‐inspired device miniaturizes up to sixfold for syringe insertion and autonomously unfolds post‐implantation.
Selin Olenik   +13 more
wiley   +1 more source

BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS [PDF]

open access: yesJournal of Engineering Science and Technology, 2015
Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding ...
S. C. LIM   +4 more
doaj  

Home - About - Disclaimer - Privacy