Results 61 to 70 of about 529,740 (187)
Acoustic Vector-Corrected Impedance Meter [PDF]
We describe the development of a novel instrument intended for the measurement of the acoustical reflection coefficient of materials. The instrument effectively implements a one-port vector-corrected network analyzer in the acoustic, rather than the ...
Scott, Jonathan B., Pennington, Kyle
core +1 more source
Wide-band modelling of tower-footing grounding systems based on the impulse response measurement [PDF]
The tower footing grounding system is of major importance for analysis of the lightning overvoltages on an overhead transmission line during backflashover and shielding failure.
Jasika Ranko +3 more
doaj
Coronary input impedance during cardiac cycle as determined by impulse response method
The coronary arterial system was characterized by its input impedance determined in systole and diastole from impulse response functions in five dogs. The impulse response technique was verified on a known hydraulic system.
N. Westerhof, P. Sipkema, G. A. Van Huis
core +1 more source
Arcing High Impedance Fault Detection Using Real Coded Genetic Algorithm
Safety and reliability are two of the most important aspects of electric power supply systems. Sensitivity and robustness to detect and isolate faults can influence the safety and reliability of such systems.
Zamanan, N. +2 more
core +1 more source
There is a great difference between the transient response characteristics and the power frequency response characteristics of the grounding device under lightning strike. Its grounding impedance decreases under the action of soil impulse characteristics.
Qirui WANG +5 more
doaj +1 more source
Impulsive impedances in lossless circuits: Fourierand Laplace methods
A proposal for adding impulsive components of impedance/admittance to the reactance/susceptance for lossless transmission lines is extended to all lossless resonant circuits. This new Fourier analysis yields a finite rate of energy transfer from a lossless source while the orthodox analysis would give an unbounded steady-state energy transfer.
openaire +1 more source
The growing deployment of single-phase inverters in residential low-voltage distribution networks poses new challenges to system stability and power quality.
Ian Paul Gerber +2 more
doaj +1 more source
Early Fault Identification Method of Medium Voltage Cable Based on Impulse Impedance Characteristics
ObjectiveCables are widely used in urban distribution networks due to their high reliability, strong environmental adaptability, and low maintenance costs, gradually replacing traditional overhead lines and becoming a key component of urban power ...
ZHANG Xiang +5 more
doaj
Bayesian Time-Domain Ringing Suppression Approach in Impulse Ultrawideband Synthetic Aperture Radar
Impulse ultrawideband (UWB) synthetic aperture radar (SAR) combines high-azimuth-range resolution with robust penetration capabilities, making it ideal for applications such as through-wall detection and subsurface imaging.
Xinhao Xu +7 more
doaj +1 more source
1. Intallation body; 2. Impulse bag filter; 3.Cyclone separator; 4. Cyclone dryer; 5. Impulse dryer; 6. Helical feeder; 7. Air inlet pipe; 8. Air filter; 9. Air regulating valve; 10. Fan; 11. Feed port; 12. Air inlet port; 13. Exhaust port; 14.
Feng Chen (25347) +2 more
core +1 more source

