Results 11 to 20 of about 506,254 (285)

Use of Impulse Oscillometry in Patients with Chronic Obstructive Pulmonary Disease [PDF]

open access: yesThoracic Research and Practice
OBJECTIVE: Although spirometry is a standard diagnostic tool for obstructive lung diseases, it is rarely performed, and the quality of basic spirometry is low in many countries. The impulse oscillometry system (IOS) is a non-invasive method that requires
Burcu Öztürk Şahin, Nurdan Köktürk
doaj   +2 more sources

Modeling of different tower grounding systems using hybrid continuous circuit-trapezoidal integration method [PDF]

open access: yesSerbian Journal of Electrical Engineering, 2021
In order to protect the transmission lines against lightning strikes, it is important to investigate the tower grounding system. In this paper, a recent method called hybrid continuous circuit-trapezoidal integration method is used to calculate ...
Asadpourahmadchali Mohammadbagher   +2 more
doaj   +1 more source

Non-destructive characterisation of structural ceramics using impedance spectroscopy [PDF]

open access: yes, 2001
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.The aim of this project was to explore the potential applications of impedance spectroscopy (IS) in the non-destructive characterisation of structural ...
Wang, Xin
core   +7 more sources

Back flashover mitigation for transmission tower by parallel additional multiple conductors from tower top to ground footage to alter the surge impedance

open access: yesEnergy Reports, 2022
This research assessed the transmission tower’s surge impedance before and after paralleling the overhead ground wire (OHGW) made of twisted galvanized steel cable from topmost of the transmission tower to the tower ground footage.
Chakkri Satchathampitak   +2 more
doaj   +1 more source

Evaluation principle and method of horizontal grounding electrode based on time‐varying impedance

open access: yesIET Science, Measurement & Technology, 2021
The length of the horizontal grounding electrode is usually extended to decrease the impulse grounding resistance. In this paper, the mechanism for influencing the effective length is revealed by studying the dispersal process of a horizontal electrode ...
Xiaobin Cao   +5 more
doaj   +1 more source

On the Characterisations of the Impulse Breakdown in High Resistivity Soils by Field Testing

open access: yesEnergies, 2021
This paper presents experimental results of high-current impulse tests on six ground electrode configurations. A high impulse current generator is employed to inject different magnitudes of current into these rod electrodes, under both positive and ...
Abdul Wali Abdul Ali   +1 more
doaj   +1 more source

Measurement and analysis of impulse grounding impedance of tower grounding device subjected to artificial lightning M‐component

open access: yesIET Generation, Transmission & Distribution, 2023
The impulse grounding impedance of tower grounding device is one of the important factors in the lightning protection evaluation of transmission line. The impulse characteristic test of the actual tower grounding device under lightning was rarely carried
Yi Zhang   +7 more
doaj   +1 more source

Review: Factors Affecting the Performance of Ground Electrodes under High Impulse Currents

open access: yesEnergies, 2023
Most studies have observed that the impedance values of ground electrodes under high impulse conditions (Zimp) are lower than the resistance values under steady-state conditions (RDC).
Normiza Mohamad Nor
doaj   +1 more source

Impulse Characteristics of Highly Wetted Soils [PDF]

open access: yesJournal of Electrical and Electronics Engineering, 2023
It has been well accepted that under high impulse conditions, ionisation process in soil would occur, causing the ground resistance value to fall to a lower value than that obtained at low voltage low current, RDC.
REFFIN Muhd Shahirad   +4 more
doaj  

Research on large-capacity impulse test technology for distribution transformer based on energy storage intelligent power

open access: yesEnergy Reports, 2022
Large-capacity impulse test of distribution transformer requires a large amount of instantaneous energy, while the impulse mode of conventional dedicated high-voltage line and generator requires synchronous switch, adjusted impedance, generator, etc ...
Bo Niu   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy