Results 61 to 70 of about 4,880 (169)

Inappropriate shocks from a subcutaneous implantable cardioverter-defibrillator due to oversensing during periods of rate-related bundle branch block

open access: yesJournal of Arrhythmia, 2017
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a novel technology with proven efficacy in sudden cardiac death prevention; however, there is a lack of long-term safety data.
Maria João Sousa, MD, Tim Betts, MD
doaj   +1 more source

ICD programming

open access: yesIndian Heart Journal, 2014
Background: Appropriate ICD programming is the key to prevent inappropriate shock delivery, that is closely associated to a negative patients' outcome. Methods: Review of the literature on ICD therapy to generate ICD programmings that can be applied to ...
Mauro Biffi
doaj   +1 more source

Systematic review of physical and dosimetric criteria for managing CIEDs in radiotherapy: A medical physicist's perspective

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta   +15 more
wiley   +1 more source

Revision of subcutaneous implantable cardioverter defibrillator to intermuscular pocket to prevent inappropriate shocks

open access: yesClinical Case Reports, 2020
Sensing and defibrillation threshold for a S‐ICD are impacted by positioning at implant or revision. The intermuscular pocket prevents device migration and provides appropriate, stable sensing vectors.
Jeko M. Madjarov   +4 more
doaj   +1 more source

Advancements in Enzymatic Biofuel Cells for Wearable Electrochemical Biosensors: Powering Point‐of‐Care Health Monitoring

open access: yesAdvanced Sensor Research, Volume 5, Issue 8, August 2026.
Advances in enzymatic biofuel cells are highlighted through innovative electrode architectures, enzyme immobilization strategies, and hybrid integration with triboelectric, piezoelectric, and thermoelectric energy harvesters. These emerging approaches improve power output, operational stability, and biocompatibility, advancing self‐powered wearable and
Rashid Khan   +3 more
wiley   +1 more source

A Case of Silicone Allergy Induced by a Subcutaneous Implantable Cardioverter Defibrillator

open access: yesJournal of Arrhythmia, Volume 42, Issue 4, August 2026.
A 54‐year‐old man developed a granulomatous lesion 7 months after S‐ICD implantation and generator exposure 6 years later. Negative infection workup and positive patch testing supported silicone‐related hypersensitivity. To our knowledge, this is the first reported case of silicone allergy associated with an S‐ICD system.
Wataru Shinkai   +9 more
wiley   +1 more source

Inappropriate Shocks in Patients with ICDs: Single Chamber versus Dual Chamber

open access: yesArquivos Brasileiros de Cardiologia, 2013
Despite the technological evolution of the implantable defibrillator, one of the questions that remains is the possible benefit of the dual chamber versus single chamber implantable cardioverter defibrillator (ICD) in reducing inappropriate shocks.To evaluate which type of device provides fewer inappropriate shocks (dual chamber versus single chamber ...
Gonçalves, Juliana, Pereira, Telmo
openaire   +2 more sources

Long‐term safety and efficacy of subcutaneous implantable cardioverter‐defibrillator compared with transvenous implantable cardioverter‐defibrillator in propensity score‐matched patients from Japan

open access: yesJournal of Arrhythmia
Background Subcutaneous implantable cardioverter‐defibrillator (S‐ICD) has been reported to be non‐inferior to transvenous ICD (TV‐ICD) in terms of device‐related complications and inappropriate shock (IAS).
Yuki Konno   +12 more
doaj   +1 more source

Early inappropriate shock in a subcutaneous cardiac defibrillator due to subcutaneous air

open access: yesJournal of Arrhythmia, 2019
A 57‐year‐old man was admitted to our hospital due to syncopal attack. He was diagnosed with Brugada syndrome due to which a subcutaneous implantable cardiac defibrillator (S‐ICD) was inserted using the standard technique.
Ryo Nishinarita   +12 more
doaj   +1 more source

Home - About - Disclaimer - Privacy