Inappropriate ICD shocks after collision with a pole
A 60-year-old man experienced inappropriate ICD shocks after collision with a pole. Cine-fluoroscopy demonstrated lead fracture of the proximal lead, which was not so clearly visible on the chest radiograph.
Yap, Sing Chien; id_orcid +2 more
core +10 more sources
Inappropriate defibrillator shock due to oversensing. What is the mechanism?
Implantable cardioverter defibrillator (ICD) is often advised for secondary prevention of sudden cardiac death. Inappropriate shocks from ICD is uncommon but can seriously affect the quality of life.
Debabrata Bera +5 more
doaj +1 more source
Key Clinical Message R‐wave double counting is a rare cause of ventricular oversensing that can lead to inappropriate shocks. Optimizing device programming is essential for the avoidance of subsequent inappropriate therapies.
Athanasios Saplaouras +9 more
doaj +1 more source
The automatic implantable cardioverter-defibrillator: Evaluating suspected inappropriate shocks [PDF]
Two patients who received inappropriate shocks from an implanted defibrillator are presented. In one case, fracture of a sensing lead was responsible and in the other case, sensing of both pacemaker stimuli and the evoked ventricular electrogram resulted
Troup, Paul, Chapman, Peter D.
core +1 more source
Properties of mass-loading shocks, 2. Magnetohydrodynamics [PDF]
The one-dimensional magnetohydrodynamics of shocked flows subjected to significant mass loading are considered. Recent observations at comets Giacobini-Zinner and Halley suggest that simple nonreacting MHD is an inappropriate description for active ...
Oughton, Sean +3 more
core +1 more source
ICD discrimination of SVT versus VT with 1:1 V-A conduction: A review of the literature
Inappropriate ICD shocks are associated with increased mortality. They also impair patients' quality of life, increase hospitalizations, and raise health-care costs. Nearly 80% of inappropriate ICD shocks are caused by supraventricular tachycardia.
Rhanderson N. Cardoso +3 more
doaj +1 more source
Pseudo Inappropriate Shock: A Technical Dilemma
With liberal availability of high end cardiac implantable devices in recent era, we frequently encounter patients who are recipients of implantable cardioverter defibrillators (ICDs) in our routine clinical practice. Despite improvements in shock detecting algorithms by various manufacturers, incidence of inappropriate shock therapy remains high, it is
Pujan J Shah, Aditya Kapoor
openaire +3 more sources
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II Frequency, Mechanisms, Predictors, and Survival Impact [PDF]
ObjectivesThis study sought to identify the incidence and outcome related to inappropriate implantable cardioverter-defibrillator (ICD) shocks, that is, those for nonventricular arrhythmias.BackgroundThe MADIT (Multicenter Automatic Defibrillator ...
Higgins, Steven L. +13 more
core +1 more source
Jennifer Llewellyn,1 Erin Barker,2 Catherine Bowe,2 Natalie Hallas,3,* Ralphael Oghagbon,3,* Archana Rao1 1Liverpool Heart and Chest Hospital, Liverpool, UK; 2York Health Economics Consortium, University of York, Heslington, York, UK; 3Medtronic,
Llewellyn J +5 more
doaj
‘Life-saving’ inappropriate ICD shock [PDF]
An 81-year-old female patient with ischaemic cardiomyopathy and an ICD implanted for secondary prevention received a shock while showering. The ICD interrogation revealed that a bodily conduction of the mains electric current caused the shock. Similar previously stored episodes …
openaire +2 more sources