An 88-year-old female presented with inappropriate implantable cardioverter-defibrillator shocks. Interrogation revealed lead noise sensed as ventricular fibrillation, leading to 11 shocks in 1 day. A defibrillation at the period of maximal vulnerability
Ilya V. Ryaboy, MD, Mark E. Peele, MD
doaj +1 more source
Relating Occupational Exposure to Persistent Health Effects
The objectives of the Workshop are addressed using epidemiologic data from population groups in occupations involving exposure to hand-transmitted vibration and/or shocks.
Anthony J. Brammer, Magdalena F. Scholz
doaj +1 more source
CyberKnife can cause inappropriate shock
Implantable cardioverter-defibrillators (ICD) have been increasingly used to treat life-threatening ventricular tachyarrhythmias. Although they have life-saving capabilities, they are very sensitive to electromagnetic energy sources. It has been reported that many problems associated with the detection of tachyarrhythmias and termination of the ...
Nazmiye, Cakmak +3 more
openaire +2 more sources
Background PRAETORIAN is the first randomized controlled trial that demonstrated the noninferiority of subcutaneous ICD (S‐ICD) in comparison with transvenous ICD (TV‐ICD).
Dibbendhu Khanra +14 more
doaj +1 more source
Inappropriate ICD Shock as a Result of TASER Discharge
Conducted energy weapon (commonly known as TASER) discharge in patients with implantable cardioverter-defibrillators is known to cause electromagnetic interference and inappropriate ventricular fibrillation sensing without delivery of implantable cardioverter-defibrillators therapy during conducted energy weapon application.
Chirag R. Barbhaiya, MD +9 more
openaire +3 more sources
An inappropriate shock after reprogramming tachycardia zones [PDF]
AbstractA patient with an implantable cardioverter‐defibrillator (ICD) (Abbott®) had episodes of slow monomorphic ventricular tachycardia (VT) and his ICD was programmed with three tachycardia zones. During the follow‐up, he received an inappropriate shock.
Rita Marinheiro +9 more
openaire +3 more sources
Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease [PDF]
ObjectiveInappropriate implantable cardioverter defibrillator (ICD) shocks in children and patients with congenital heart disease (CHD) remain a major complication of device therapy, occurring in as many as 50% of children with ICDs.
Goldstein, Stephanie A. +13 more
core +1 more source
BackgroundIn US clinical practice, many patients who undergo placement of an implantable cardioverter‐defibrillator (ICD) for primary prevention of sudden cardiac death receive dual‐chamber devices.
Pamela N. Peterson +18 more
doaj +1 more source
Implantable Cardioverter‐Defibrillator Shock: Appropriate or Inappropriate? [PDF]
A 76‐year‐old female with a single chamber implantable cardioverter‐defibrillator implanted for secondary prevention was referred due to multiple discharges. The device was programmed for ventricular tachycardia (VT) detection at 400 ms, fast VT detection at 280 ms, and ventricular fibrillation detection at 320 ms.
Michael A, Nault +6 more
openaire +2 more sources
Electromagnetic interference (EMI) includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation.
Edward Samuel Roberto +3 more
doaj +1 more source