Results 11 to 20 of about 3,801 (279)
New Approach to Evaluate the Transformation Accuracy of Inductive CTs for Distorted Current
This paper presents a newly developed method to determine the values of current error and phase displacement for the transformation of distorted current harmonics by the inductive current transformers.
Michal Kaczmarek, Ernest Stano
doaj +3 more sources
Nanocrystalline material provides an opportunity to improve the wideband performance of inductive current transformers and enables the possibility of ensuring their transformation accuracy for distorted and sinusoidal current from 50 Hz up to 20 kHz ...
Michal Kaczmarek, Kaczmarek Michal
exaly +4 more sources
Use of COMTRADE Fault Current Data to Test Inductive Current Transformers [PDF]
This paper presents a study on the inductive current transformer behaviour when subjected to distorted actual waveforms. Typical tools adopted to deal with such a condition, as the well-known ratio error, phase error, frequency response, etc. not always provide satisfactory results in all the possible operating condition. In addition, Standards lack in
Mingotti, Alessandro +3 more
openaire +4 more sources
Amplification of S-1 Spheromak current by an inductive current transformer [PDF]
We attempt to predict the consequences of adding an inductive current transformer (OH Transformer) to the present S-1 Spheromak experiment. Axisymmetric modeling with only classical dissipation shows an increase of toroidal current and a shrinking and hollowing of the current channel, conserving toroidal flux.
Jardin, S. C., Janos, A., Yamada, M.
openaire +3 more sources
Estimation of the inductive current transformer derating for operation with distorted currents
Abstract The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current.
Kaczmarek, Michał, Kaczmarek, M.
openaire +2 more sources
The traditional ferromagnetic resonance model of the inductive voltage transformer in the IEC/TR 61869-102 transformer standard ignores the DC resistance of the transformer.
Hongwen Liu +3 more
doaj +2 more sources
Improving the Electricity Quality by Means of a Single-Phase Solid-State Transformer
The paper describes the use of a single-phase three-stage solid-state transformer in networks with non-sinusoidal voltages in order to improve the quality of electricity. An active-inductive load was chosen as the load.
Boris Avdeev +2 more
doaj +2 more sources
Are Inductive Current Transformers Performance Really Affected by Actual Distorted Network Conditions? An Experimental Case Study [PDF]
The aim of this work is to assess whether actual distorted conditions of the network are really affecting the accuracy of inductive current transformers.
Alessandro Mingotti +4 more
doaj +3 more sources
This paper explores the implications of employing a load exhibiting a power factor of 1 to test the transformation accuracy of an inductive current transformer with an apparent power below 5 VA. It offers an explanation of the change in current error and
Michał Kaczmarek
doaj +2 more sources
Thermal Aspect in Operation of Inductive Current Transformers and Transducers
An increase in the temperature of the magnetic core causes narrowing of its hysteresis loop and reduction in the saturation magnetic flux density. Therefore, at the same operating point on the magnetization characteristic, the nonlinear effect may become
Michal Kaczmarek, Artur Szczesny
doaj +2 more sources