Results 21 to 30 of about 3,801 (279)
Ensuring the optimal performance of power transformers is a laborious task in which the insulation system plays a vital role in decreasing their deterioration.
Manuel J. Jiménez-Navarro +3 more
doaj +2 more sources
Design of a Current-Transformer Based Inductive Coupler for Power-Line Communications
In this paper, the design of a current-transformer based inductive coupler for power-line communications is documented. A worst-case design is presented in a step-by-step fashion and experimentally confirmed by doing verification measurements in the ...
Petrus A. Janse Van Rensburg +2 more
openaire +2 more sources
In this review article, ideas for the development of measuring methods and setups to test inductive instrument transformer accuracy for the transformation of distorted current or voltage are analyzed. This article proposes limiting values for ratio error
Michal Kaczmarek, Ernest Stano
doaj +1 more source
There is a need for induction filter technology in the field of low-voltage distribution networks. This paper proposes an induction filter distribution transformer with a unique Dd0yn11 three-winding configuration. This approach allows for the control of
Xiao Zhang +3 more
doaj +1 more source
This paper discusses three methods of modulation for a single-phase isolated matrix converter. The matrix converter is combined with a transformer integration to perform power decoupling control in order to reduce the number of component and capacitor ...
Goh Teck Chiang, Takahide Sugiyama
doaj +1 more source
Voltage transient management for Alternating Current trains with vacuum circuit breakers
Alternating current power supplies and rolling stock with 25 kV (50 or 60 Hz) and 15 kV (16.7 Hz) traction systems do not have the characteristics and behaviour of a typical three‐phase medium‐voltage distribution system. Switching inductive loads with a
Thomas Moore +2 more
doaj +1 more source
In this paper a comparison of the wideband power sources of a pulse width modulation (PWM) inverter and a power supply composed of an audio power amplifier and a two-channel arbitrary generator is discussed.
Michal Kaczmarek, Piotr Kaczmarek
doaj +1 more source
Although oscillating switching impulse (OSI) voltage is recommended for the transformer field test, the lack of corresponding fault diagnosis technologies limits its application in the field.
Xuanrui Zhang +5 more
doaj +1 more source
Feasibility of applying inductive filtering technology to the HVDC transmission system
This study explores the feasibility of applying inductive filtering technology to high-voltage direct-current (HVDC) transmission system since only filtering in the net side may lead to a lot of harmonics in the converter transformer. Basic principles of
Shang Rong-Yan +2 more
doaj +1 more source
Influence of transformer leakage inductance on DC high current generator
Abstract The efficiency is affected by the parameters of components in the DC high current generator. The leakage inductance of the rectifier transformer will affect the output and filtering effect of the device and reduce the power quality of the public network. To improve the output and filtering effect of the DC high current generator,
Z Y Liu +5 more
openaire +1 more source

