Results 21 to 30 of about 153,268 (299)
A Novel Differential High-Frequency Current Transformer Sensor for Series Arc Fault Detection
Fault arc detection is an important technology to ensure the safe operation of electrical equipment and prevent electrical fires. The high-frequency noise of the arc current is one of the typical arc characteristics of almost all loads.
Guanghai Bao +3 more
doaj +2 more sources
There is a need for induction filter technology in the field of low-voltage distribution networks. This paper proposes an induction filter distribution transformer with a unique Dd0yn11 three-winding configuration. This approach allows for the control of
Xiao Zhang +3 more
doaj +1 more source
This paper discusses three methods of modulation for a single-phase isolated matrix converter. The matrix converter is combined with a transformer integration to perform power decoupling control in order to reduce the number of component and capacitor ...
Goh Teck Chiang, Takahide Sugiyama
doaj +1 more source
Voltage transient management for Alternating Current trains with vacuum circuit breakers
Alternating current power supplies and rolling stock with 25 kV (50 or 60 Hz) and 15 kV (16.7 Hz) traction systems do not have the characteristics and behaviour of a typical three‐phase medium‐voltage distribution system. Switching inductive loads with a
Thomas Moore +2 more
doaj +1 more source
Transformer Grammars: Augmenting Transformer Language Models with Syntactic Inductive Biases at Scale [PDF]
We introduce Transformer Grammars (TGs), a novel class of Transformer language models that combine (i) the expressive power, scalability, and strong performance of Transformers and (ii) recursive syntactic compositions, which here are implemented through
Laurent Sartran +5 more
semanticscholar +1 more source
Improving the Electricity Quality by Means of a Single-Phase Solid-State Transformer
The paper describes the use of a single-phase three-stage solid-state transformer in networks with non-sinusoidal voltages in order to improve the quality of electricity. An active-inductive load was chosen as the load.
Boris Avdeev +2 more
doaj +1 more source
The traditional ferromagnetic resonance model of the inductive voltage transformer in the IEC/TR 61869-102 transformer standard ignores the DC resistance of the transformer.
Hongwen Liu +3 more
doaj +1 more source
In this paper a comparison of the wideband power sources of a pulse width modulation (PWM) inverter and a power supply composed of an audio power amplifier and a two-channel arbitrary generator is discussed.
Michal Kaczmarek, Piotr Kaczmarek
doaj +1 more source
Influence of transformer leakage inductance on DC high current generator
Abstract The efficiency is affected by the parameters of components in the DC high current generator. The leakage inductance of the rectifier transformer will affect the output and filtering effect of the device and reduce the power quality of the public network. To improve the output and filtering effect of the DC high current generator,
Z Y Liu +5 more
openaire +1 more source
On fully superconducting rectifiers and fluxpumps. A review. Part 2: Commutation modes, characteristics and switches [PDF]
This paper forms the second part of the review. Full and half wave superconducting transformer rectifiers are analysed. Modes of operation and loss mechanisms are detailed and a comparison between the behaviour of dynamos and rectifiers is presented ...
Kate, H.H.J. ten +1 more