Results 71 to 80 of about 31,266 (238)

Molecular characterization of covRS mutations in M1UK Streptococcus pyogenes

open access: yesFEBS Open Bio, EarlyView.
Group A Streptococcus (GAS) acquires covRS mutations driving a hypervirulent bacterial state, frequently associated with invasive disease‐like necrotizing fasciitis. We demonstrate that the newly emerged M1UK GAS lineage can also acquire these mutations.
Jarrad Pritchard   +12 more
wiley   +1 more source

Precisión en flujo de infusión programado de bombas de nutrición enteral Precision in programmed infusion flow of enteral nutrition pumps

open access: yesActa Médica Costarricense, 2008
Justificación y objetivo: Se evaluó in vitro la precisión en el flujo de nutrición enteral en bombas peristálticas de nutrición enteral con el fin de determinar si ésta puede ser una variable que cause errores en la administración de la fórmula ...
Juan Ignacio Padilla-Cuadra   +4 more
doaj  

Implementing smart infusion pumps with dose-error reduction software: real-world experiences

open access: yes, 2017
Intravenous (IV) drug administration, especially with ‘smart pumps’, is complex and susceptible to errors. Although errors can occur at any stage of the IV medication process, most errors occur during reconstitution and administration.
Claire Heron
core   +1 more source

The Effect Of Interface Type On Visual Error Checking Behavior [PDF]

open access: yes, 2015
During data entry tasks, small errors can result in catastrophe, for instance adding an extra zero to a drug dose when programming an infusion in a hospital. For this reason understanding users’ error checking behavior is highly important.
Cox, Anna L.   +9 more
core   +1 more source

A new flow chip in combination with multiphoton microscopy as a protocol for longitudinal 3D imaging of tissue calcification under shear stress

open access: yesFEBS Open Bio, EarlyView.
Miniaturized flow chip platform enabling continuous perfusion and longitudinal multiphoton 3D imaging of vascular smooth muscle cell constructs under physiological flow. Brightfield imaging guides region selection, while CellTracker Green and mRuby‐labeled fetuin‐A visualize cells and mineral deposition, respectively. Magnesium supplementation markedly
Vytautas Kučikas   +6 more
wiley   +1 more source

Long‐Term Follow‐Up of Chemotherapy‐Associated Biological Aging in Women With Early Breast Cancer

open access: yesAging and Cancer, EarlyView.
Women threated with adjuvant chemotherapy for early breast cancer have sustained long‐term increase in p16INK4a,, a robust marker of cell senescence, suggesting a chemotherapy‐associated age acceleration. p16INK4a as well as other biomarkers may identify patients at greatest risk for senescence‐related diseases of aging.
Hyman B. Muss   +12 more
wiley   +1 more source

Sistema para avaliação da funcionalidade de bombas de infusão [PDF]

open access: yes, 2004
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica.A grande maioria dos equipamentos utilizados nos hospitais foi desenvolvida para operar dentro de normas rígidas de ...
Silva Júnior, Álvaro Martins da
core  

Super‐Refractory Status Epilepticus (SRSE) in a Patient With Compound Heterozygous OPA1 Variants: Case Report and Literature Review

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Super‐Refractory Status Epilepticus (SRSE) is a rare, life‐threatening neurological emergency with unclear etiology in many cases. Mitochondrial dysfunction, often due to disease‐causing genetic variants, is increasingly recognized as a cause, with each gene producing distinct pathophysiological mechanisms.
Pouria Mohammadi   +2 more
wiley   +1 more source

HEMOLYSIS OF ERYTHROCYTES IN INTRAVENOUS INFUSION DEVICES: AN INTEGRATIVE REVIEW OF THE LITERATURE

open access: yesCogitare Enfermagem, 2015
Extracorporeal hemolysis may be identified during hemotherapy. The nurse is one of the professionals responsible for the administration of blood components and the control of possible risks, and must therefore acquire the knowledge which supports ...
Larissa Perez Pardo   +4 more
doaj   +1 more source

Flow Rate Variability from Selected syringe and Mobile Infusion Pumps

open access: yes, 1988
Alterations in response to pharmacological agents have been attributed to flow rate variation produced by intravenous infusion devices during drug delivery. A wide range of variation has been shown to occur with large-volume infusion devices. The intent
Jill C. Stull   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy