Results 21 to 30 of about 9,639,269 (244)
This article presents a Fifteen‐level inverter topology that has a lesser number of switches (12) and can accommodate isolated DC sources. The total harmonic elimination (THD) of the proposed topology using genetic algorithm is within the IEEE 519 standards. Further, the fifteen‐level inverter is implemented in Hardware and firing pulses were generated
Yogesh Joshi +4 more
wiley +1 more source
The direct matrix converter is a well-accepted topology for AC/AC converters. The commutation method should be considered in the direct matrix converter topology to avoid failures caused by the input short circuit and output open circuit during ...
Sahel Solemanifard +3 more
semanticscholar +1 more source
The automatic reclosing strategy is an effective measure to improve the reliability of a distribution network. It can quickly clear instantaneous faults in the grid.
Weijie Xie +5 more
semanticscholar +1 more source
A Soft-Start-Based Method for Active Suppression of Magnetizing Inrush Current in Transformers
The occurrence of high-amplitude magnetizing inrush current during the energization of a transformer without load poses significant challenges to the stable operation of both the transformer and the power grid, potentially leading to malfunctions in ...
Chunyan Li +3 more
semanticscholar +1 more source
To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances.
Haiguo Li +4 more
semanticscholar +1 more source
In recent years, the zero-mode inrush current of high-impedance transformer with built-in high-voltage winding (T-Hin), which has large amplitude and decays slowly, causes the misoperation of zero-sequence overcurrent protection.
Wenbin Cao +5 more
doaj +1 more source
U ovom radu opisani su fenomeni i problemi do kojih dolazi prilikom priključenja transformatora na elektroenergetsku mrežu. Prilikom direktnog priključenja transformatora na mrežu (čak i u praznom hodu) dolazi do pojave visokih tranzijentnih iznosa struje koja može imati razne negativne posljedice. Tranzijentna struja može imati iznos i do desetak puta
Meštrović, Zvonimir +2 more
openaire +3 more sources
Implications of fault current limitation for electrical distribution networks [PDF]
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M. +5 more
core +1 more source
This paper proposes the inrush current suppressor using an AC chopper in a large-capacity wind power generation system (WPGS) with two squirrel-cage induction machines (SCIMs), which are switched over depending on the wind speed. The input side of the AC
Sho Shibata +3 more
doaj +1 more source
When the electromagnetic transients occur in a power transformer, an inrush current is generated in its winding. The inrush current not only affects the performance of the transformer windings, but also affects the lifetime of the transformer.
Wenqi Ge +4 more
doaj +1 more source