Results 101 to 110 of about 12,003 (292)

A 192nW inverter-based chopper instrumentation amplifier for micropower ECG applications

open access: yes, 2014
This paper proposes a low-power inverter-based chopper instrumentation amplifier (IA) for ECG applications. A capacitively-coupled topology with chopper is employed while a two-stage inverter-based amplifier serves as the gain stage. Pseudo resistors are
Wang, Jiayi   +15 more
core   +1 more source

The Implementation of a High-Performance Glucose Biosensor Based on Differential EGFET and Chopper Amplifier

open access: yesIEEE Journal of the Electron Devices Society
In this paper, a new architecture for glucose biosensors is proposed, which adopts a Chopper amplifier instead of a conventional instrumentation amplifier (INA) and differential extended gate field effect transistor (EGFET) as the input stage.
Po-Yu Kuo   +10 more
doaj   +1 more source

Integration of Low‐Voltage Nanoscale MoS2 Memristors on CMOS Microchips

open access: yesAdvanced Functional Materials, EarlyView.
This article presents the first monolithic integration of nanoscale MoS2‐based memristors into the back‐end‐of‐line of foundry‐fabricated CMOS microchips in a one‐transistor‐one‐resistor (1T1R) architecture. The MoS2‐based 1T1R cells exhibit forming‐free, nonvolatile resistive switching with ultra‐low operating voltages, low cycle‐to‐cycle variability ...
Jimin Lee   +16 more
wiley   +1 more source

Swelling‐Programmed Topographical Guidance for Dynamic Spheroid Self‐Assembly via a Mechanochemical Hydrogel Niche

open access: yesAdvanced Functional Materials, EarlyView.
A swelling‐programmed micropatterned hydrogel guides adherent cells through a controlled transition from cell–matrix anchoring to cadherin‐mediated cell–cell compaction, enabling rapid assembly of high‐viability spheroids with defined size and morphology.
Han Gyeol Nam   +8 more
wiley   +1 more source

Development of a direct-circuit amplifier for spacecraft instrumentation systems

open access: yes, 1968
Direct circuit amplifier for spacecraft instrumentation ...
Cree, D.
core  

Exploring an Alternative to mRNA Vaccine Cold Chain Storage: MRNA‐Lipid Nanoparticle Stability When Dried in a Polymer Matrix

open access: yesAdvanced Functional Materials, EarlyView.
The nanostructure, size, and function of mRNA‐loaded lipid nanoparticles are evaluated before drying, within polymer microneedles, and after rehydration. The results reveal the polymer and LNP loadings required to recover nanostructure and preserve the delivery performance in dry‐state formulations.
Brendan P. Dyett   +19 more
wiley   +1 more source

Titanium Suboxides Responsible for Electronic Anomaly Near Room Temperature in the Ti3C2Tx MXene

open access: yesAdvanced Functional Materials, EarlyView.
Our multi‐technique study reveals that the near‐room‐temperature anomaly in Ti3C2Tx MXene is linked to titanium suboxide nanodomains, including Ti3O5, embedded within the MXene host. Their temperature‐driven transformation provides an alternative explanation to solvent‐ and swelling‐based models and offers new insight into the thermally activated ...
Bence G. Márkus   +8 more
wiley   +1 more source

Near‐Infrared Light‐Driven Zn/Au Janus Micromotors for Multiplex SERS Detection of Anticancer Drugs

open access: yesAdvanced Functional Materials, EarlyView.
Zn/Au Janus micromotors, propelled by thermophoretic effects under NIR light, function as active SERS platforms for single and multiplex detection of anticancer drugs. Their dynamic motion enhances analyte exchange at the Au interface, reducing saturation and competitive adsorption, thereby improving sensitivity and extending the linear detection range.
Tijana Maric   +8 more
wiley   +1 more source

Glissile Interphase Boundaries Enable Collective Phase Switching in Epitaxial Polar Oxides

open access: yesAdvanced Functional Materials, EarlyView.
A triple point is identified in the phase diagram of low‐symmetry epitaxial BiFeO3 thin film along with an extended regime of phase competition associated with a flattened energy landscape. The electromechanical response is shown to be governed by correlated interphase‐boundary motion, including scale‐free avalanche dynamics characteristic of systems ...
Mohammad Moein Seyfouri   +11 more
wiley   +1 more source

A 1.87 µW Capacitively Coupled Chopper Instrumentation Amplifier with a 0.36 mV Output Ripple and a 1.8 GΩ Input Impedance for Biomedical Recording

open access: yesJournal of Low Power Electronics and Applications
Chopper and capacitively coupled techniques are employed in instrumentation amplifiers to create capacitively coupled chopper instrumentation amplifiers (CCIAs) that obtain a high noise power efficiency.
Xuan Phuong Tran   +4 more
doaj   +1 more source