Results 31 to 40 of about 54,547 (303)

Impact of First Tower Earthing Resistance on Fast Front Back-Flashover in a 66 kV Transmission System

open access: yesEnergies, 2020
Lightning stroke on a transmission tower structure is one of the major reasons that results in high voltages at the tower arms due to the excessive lightning current flowing through the transmission tower to earth.
Abdullah H. Moselhy   +3 more
doaj   +1 more source

Non-uniform Pollution Method and Pollution Flashover Characteristics of Transmission Line Insulators

open access: yesZhongguo dianli, 2019
At present, pollution of insulators in artificial contamination test is done by uniform smearing, but natural pollution, affected by wind, raining, insulator shape, pollution, pollutant particle size and other factors, is a non-uniform accumulation on ...
Qin LIU, Yiwen WANG
doaj   +1 more source

Insulation co-ordination and the enlargement law for the GM counter tube [PDF]

open access: yesNuclear Technology and Radiation Protection, 2016
In this paper we analyze application of contemporary methods of insulation co-ordination and the enlargement law in designing a GM counting tube.
Dolićanin Edin Ć.   +3 more
doaj   +1 more source

An overview of biodiesel energy [PDF]

open access: yes, 2020
Over the last ten years’ attention to biofuels production has increased dramatically and become crucial. One of the main factors is the rise in world oil prices, coupled with the abatement of greenhouse gas emissions and concerns about energy security ...
Abd Halim, Muhamad Fazli   +3 more
core  

Assessment of Insulation Coordination and Overvoltage for Utility Girds Integrated with Solar Farms

open access: yesEnergies
Due to the economic and environmental concerns associated with fossil fuels, many government and private organizations are progressively shifting towards the integration of solar farms with Utility Grids.
Mansoor Soomro   +4 more
doaj   +1 more source

Development of a ±660 kV DC transmission line arrester

open access: yesThe Journal of Engineering, 2019
In order to improve the lightning withstand level of ±660 kV DC transmission line in China, the authors had begun to develop the ±660 kV DC line arrester since 2014, which was developed successfully in 2016.
Shanqiang Gu   +6 more
doaj   +1 more source

Transient Overvoltages Simulation Due to the Integration Process of Large Wind and Photovoltaic Farms With Utility Grids

open access: yesIEEE Access, 2021
Integration of the renewable energy sources with utility grids is receiving more impressive concerns to provide extra-green energy sources to work in parallel or to phase out the sources with fossil fuels. The effects of the transient surges are the most
Samy M. Ghania, Anas M. Hashmi
doaj   +1 more source

Parametric and nonparametric identification of shell and tube heat exchanger mathematical model [PDF]

open access: yes, 2012
Parametric and nonparametric models of a shell and tube heat exchanger are studied. Such models are very important because they provide information about controlling a system operation. Without the model, the control task would be difficult for tuning
Khaerudini, D. S.   +3 more
core   +1 more source

Tower Air-gaps discharge characteristics and insulation coordination for UHV AC double-circuit line

open access: yesThe Journal of Engineering, 2019
In order to give out inverse V-type insulator tower air-gaps configuration of double-circuit UHV AC power transmission line, different distance air-gaps from high-voltage electrode to tower frame discharge tests of inverse V-string are carried out ...
Huo Feng, Nan Jing, Ye Qiming, Ma Yeming
doaj   +1 more source

Prediction of switching transients in high voltage air-insulated substations [PDF]

open access: yes, 2009
Describes the process of prediction of switching transients in high voltage air-insulated ...
Judd, M.D., Musa, B.U., Siew, W.H.
core  

Home - About - Disclaimer - Privacy