Monitoring insulator contamination level under dry condition with a microwave reflectometer [PDF]
Build-up of surface contamination on high voltage insulators can lead to an increase in leakage current and partial discharge, which may eventually develop into flashover.
McMeekin, Scott +16 more
core +1 more source
Enhanced High-Voltage Power Line Insulator and Contamination Classification using Score-Level Fusion [PDF]
High-voltage (HV) power line insulators are critical for grid reliability, but their performance degrades due to contamination (e.g., salt, soot, excrement). Traditional visual inspection methods are subjective, risky, and time-consuming.
Bhusari, Balu +2 more
core
Electrical and magnetic properties of n-Cd(_1-x)Mn(_x) Te close to the metal-insulator transition [PDF]
Electrical transport and magnetic measurements have been made on n-Cd(_1-x)Mn(_x) Te (0.047 50 mT) Efros-Shklovskii variable range hopping is observed in the insulating phase.
Read, D.E., Read, Daniel Edward
core
Ex situ analyses on topological insulator films require protection against surface contamination during air exposure. This work reports on a technique that combines deposition of protective capping just after epitaxial growth and its mechanical removal ...
C. I. Fornari +6 more
doaj +1 more source
Contamination Assessment and Reduction Project (CARP), Summary of Accomplishments and Findings
The document was created for the Contamination Assessment and Reduction Project (CARP) November 2007 Conference and provides background information about the project and a summary of its accomplishments and findings.
core +1 more source
Thermal image, partial discharge and leakage current correlation of ceramic insulator under different contamination level [PDF]
This paper reports correlation on leakage current and thermograph infrared (IR) images of the ceramic outdoor insulator for the condition based monitoring purposes.
Abral, H. +5 more
core
Hierarchical Deep Feature Fusion for High-Voltage Insulator Contamination Diagnosis
The image-based identification of surface contamination on high-voltage insulators may support preventive inspection and maintenance. Existing deep learning approaches frequently employ single-stage classification, which can make it difficult to ...
Ahmet Cifci, Gurkan Bilgin
doaj +1 more source
Development of mathematical relation between ESDD and wind velocity for a contaminated insulator in Malaysia [PDF]
Insulator contamination has been identified as the most important design parameter for external insulation of the high voltage network systems. Wind and electrostatic field plays an important role in transporting and depositing of that contamination over
Buntat, Z +11 more
core
Contamination effects on charge distribution measurement of high voltage glass insulator string
It is certain that accumulated charge greatly enhances the local electric field distribution of insulator and may lead to breakdown even under nominal voltage.
Z. Adzis +5 more
core +1 more source
High voltage insulator contamination level online monitoring with conventional and novel methods
Conventional online monitoring techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and partial discharge, are not effective in dry conditions since they require the surface of the insulator to be
Jiang, Y. +17 more
core +1 more source