Results 81 to 90 of about 816,202 (285)

2D Skeletal Muscle Thin Film Actuators Enhance Efficiency of Biohybrid Robots

open access: yesAdvanced Functional Materials, EarlyView.
2D skeletal muscle thin film actuators generate millinewton‐scale forces and millimeter‐scale strokes while remaining functional for over 30 days. Their force density is 20‐fold higher than 3D skeletal muscle actuators, enabling multi‐fin robots with tunable speed and multidirectional steering.
Maheera Bawa   +5 more
wiley   +1 more source

Improving Mean Time Between Pump Failures [PDF]

open access: yes, 2018
Discussion GroupMechanical/Metallurgical design requirements for pump components Design and installation for pump baseplates Proper hydraulic fit of pumps Mechanical alignment targets/procedures Pump repair ...
Bruck, Morg   +3 more
core  

Guanosine‐Quadruplex Hydrogels as Dynamic, Mechanically Tunable and Ion Conductive 3D Scaffolds for Cell Culture Applications

open access: yesAdvanced Functional Materials, EarlyView.
Versatile guanosine‐quadruplex (GQ) hydrogels are developed as dynamic biomatrices for cell culture. These scaffolds are fabricated under mild aqueous conditions, present improved stability, tunable mechanical properties within physiological ranges; fibrillar, porous microstructure, ion conductivity, and cytocompatibility.
Neha Thakur   +10 more
wiley   +1 more source

Microfluidic Engineering of Microgels: A Review of Emerging Technologies, Materials, Fabrication Strategies, and Applications

open access: yesAdvanced Healthcare Materials, EarlyView.
Recent advances in microfluidic technologies for microgel fabrication are critically reviewed, highlighting the capabilities and limitations of major microfluidic platforms and discussing how platform design, material selection, and crosslinking strategies influence microgel architecture and functionality. Current challenges and future opportunities in
Afshin Abrishamkar   +6 more
wiley   +1 more source

Base Plate Corrosion and Premature Bearing failure in RO Pump [PDF]

open access: yes, 2018
Case StudiesOn 19th Aug 2017, abnormal noise noticed from RO (Reverse osmosis) Membrane Feed pump coupling area. Checked the vibration for pump & motor and found very high vibration at Pump Drive end. The vibration level at Pump DE Vertical recorded as 4.
Subramanian, Moorthy
core   +1 more source

Results of a post-registration clinical study of the TruCare III insulin pump in children and adolescents with type 1 diabetes mellitus

open access: yesСахарный диабет
BACKGROUND: The increase in the incidence of diabetes mellitus, including type 1 diabetes in children, is a priority issue for the national healthcare system.
E. S. Demina   +5 more
doaj   +1 more source

Effect of Sensor-Augmented Patch Pump with Predictive Low-Glucose Suspend Feature Compared to Multiple-Dose Insulin in Patients with Brittle Type 1 Diabetes

open access: yesEndocrinology Research and Practice, 2023
Objective: The conventional approach to brittle diabetes is the treatment of underlying causes and optimization with multiple-dose insulin injections. The goal of multiple-dose insulin therapy is to exactly mimic physiological insulin secretion; however,
M Temel Yılmaz   +5 more
doaj  

Hemocompatible Glycogen‐Tissue Plasminogen Activator Complexes for Enhanced Blood Clot Dissolution

open access: yesAdvanced Healthcare Materials, EarlyView.
Glycogen–heparin‐cRGD nanoparticles enable targeted delivery of tissue plasminogen activator (tPA) to thrombi through activated platelet recognition. The hemocompatible hybrids minimize interactions with blood and immune cells while retaining enzymatic biodegradability.
Nadiia Davydiuk   +6 more
wiley   +1 more source

Insulin pump therapy:A practical guide to optimising glycaemic control

open access: yes, 2014
Insulin pump services have been widely available in the UK for over 10 years. Despite this, the recent national Insulin Pump Audit identified that only 6% of patients with type 1 diabetes are managed with insulin pump therapy, far lower than anticipated.
Wilmot, Emma G.   +3 more
core   +1 more source

Design of Wireless Secure Monitoring and Controlling of Insulin Pump

open access: yesInternational Journal of Electrical Engineering and Applied Sciences, 2021
Insulin pump is a small electronic device used to help diabetes patients to control the glucose level, it can be carried easily and place under clothes.
Mortada Mohammed Abdulwahab   +4 more
doaj  

Home - About - Disclaimer - Privacy