Results 31 to 40 of about 6,729 (231)

All-Solid-State Interdigitated Micro-Supercapacitors Based on Porous Gold Electrodes

open access: yesSensors, 2023
Recent developments in embedded electronics require the development of micro sources of energy. In this paper, the fabrication of an on-chip interdigitated all-solid-state supercapacitor, using porous gold electrodes and a PVA/KOH quasisolid electrolyte,
Aymeric Pastre   +3 more
doaj   +1 more source

Fabrication and Characterization of Polyaniline/PVA Humidity Microsensors

open access: yesSensors, 2011
This study presents the fabrication and characterization of a humidity microsensor that consists of interdigitated electrodes and a sensitive film. The area of the humidity microsensor is about 2 mm2.
Ming-Zhi Yang   +2 more
doaj   +1 more source

Investigation of Behavior Stability of Activated Polyaniline Films for Gas Measurements

open access: yesProceedings, 2017
Synthesis conditions of doped polyaniline films and testing procedure affect markedly the sensor behavior and stability of them. The sensor based on such film consists of a dielectric substrate with system of metallic interdigitated electrodes on its ...
Sergey Krutovertsev   +3 more
doaj   +1 more source

Laser‐Induced Graphene from Waste Almond Shells

open access: yesAdvanced Functional Materials, EarlyView.
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova   +9 more
wiley   +1 more source

Advances in Sustainable and Wearable Textile Based Soft Robotics

open access: yesAdvanced Functional Materials, EarlyView.
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas   +6 more
wiley   +1 more source

Titanium Dioxide Nanoparticle Humidity Microsensors Integrated with Circuitry on-a-Chip

open access: yesSensors, 2014
A humidity microsensor integrated with a readout circuit on-a-chip fabricated using the commercial 0.18 μm CMOS (complementary metal oxide semiconductor) process was presented.
Yu-Chih Hu   +2 more
doaj   +1 more source

Catalytically Enhanced Near Room‐Temperature Hydrogen Sensing Using Pd‐ZnO Colloidal Crystals

open access: yesAdvanced Functional Materials, EarlyView.
Pd‐decorated ZnO colloidal crystal monolayers demonstrate excellent performance across a wide hydrogen concentration range at 33°C, with high selectivity and reproducible device fabrication. The sensors show strong responses even at low‐ppm H2 concentrations and an ultra‐low detection limit of 82 ppb, indicating their suitability for diverse hydrogen ...
Hamidah Alluhaybi   +13 more
wiley   +1 more source

A Zirconium Dioxide Ammonia Microsensor Integrated with a Readout Circuit Manufactured Using the 0.18 μm CMOS Process

open access: yesSensors, 2013
The study presents an ammonia microsensor integrated with a readout circuit on-a-chip fabricated using the commercial 0.18 μm complementary metal oxide semiconductor (CMOS) process. The integrated sensor chip consists of a heater, an ammonia sensor and a
Ming-Zhi Yang   +2 more
doaj   +1 more source

Wearable Kirigami‐Apertured Capacitive Sensors for Continuous Cardiac Volumetric Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A wearable kirigami‐apertured carbon nanotube‐paper composite (K‐CPC) capacitive sensor enables cardiac volumetric monitoring. The kirigami process creates a central aperture with cantilevered fibers that confine the electric field, enhancing both sensitivity and lateral resolution.
Yu‐Jen Cheng   +4 more
wiley   +1 more source

Decamethylferrocene oxidation at interdigitated microband array electrodes in the absence of intentionally added supporting electrolyte: experiment versus finite element model

open access: yesDiscover Electrochemistry
The one-electron oxidation of decamethylferrocene (FeCp*2) in the absence of added supporting electrolyte is investigated as a model redox system in acetonitrile to shed new light onto (i) the effect of added supporting electrolyte and (ii) the impact of
Tingran Liu   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy