Results 1 to 10 of about 18,132 (145)

Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents [PDF]

open access: yesInternational Journal of Ophthalmology, 2021
AIM: To compare the differences and consistency of IOL-Master 700 biometers applying swept optical coherence tomography with the conventional IOL-Master 500 applying partial coherence interference in terms of the ocular biological parameters in ...
Qiang Shi   +3 more
doaj   +4 more sources

Repeatability and agreement of AOCT-1000 M, RTVue XR and IOL master 500 in measuring corneal thickness mapping and axial length applying principle of optical coherence tomography [PDF]

open access: yesBMC Medical Imaging, 2023
Purpose To evaluate the repeatability and agreement of Fourier-domain optical coherence tomography (AOCT-1000 M and RTVue XR) and partial coherence interferometry biometer (IOL Master 500) in measuring corneal thickness mapping and axial length ...
Hailong Ni   +12 more
doaj   +4 more sources

Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia [PDF]

open access: yesInternational Journal of Ophthalmology, 2019
This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500.
Ya-Li Du   +7 more
doaj   +4 more sources

Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 500, IOL Master 700, and Lenstar LS900. [PDF]

open access: yesKorean J Ophthalmol, 2020
To evaluate the agreement in ocular biometry outcomes measured by three different devices, the IOL Master 500, IOL Master 700, and Lenstar LS900, and compare the refractive outcomes after cataract surgery obtained using those three devices.Medical records of 178 eyes of 89 patients who underwent ocular biometry with the three devices were ...
Song JS, Yoon DY, Hyon JY, Jeon HS.
europepmc   +4 more sources

Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 700, IOL Master 500, and Ultrasound [PDF]

open access: yesJournal of the Korean Ophthalmological Society, 2017
Purpose: To compare the new swept-source optical coherence tomography based IOL Master 700 to both the partial coherence interferometry based IOL Master 500 and ultrasound A-scan in terms of the ocular biometry and the prediction of postoperative ...
Tae Keun Yoo   +5 more
openaire   +3 more sources

Comparative Analysis of Refractive Outcomes Following Cataract Surgery Using IOL Master 500 and IOL Master 700 Biometry Devices: A Retrospective Analysis. [PDF]

open access: yesJ Clin Med
Background: This study aims to compare the refractive outcomes of cataract surgery using two different biometry devices, the IOL Master 500 and IOL Master 700, and to investigate the influence of patient-related factors on these outcomes. Methods: In this retrospective study, we analyzed data from 2994 eyes that underwent cataract surgery.
Arens S   +4 more
europepmc   +4 more sources

Comparación entre las mediciones biométricas del IOL Master 500 y el Pentacam AXL en la biometría ocular

open access: yesRevista Cubana de Oftalmología, 2021
RESUMEN Objetivo: Comparar las mediciones biométricas realizadas con el IOL Master 500 y el Pentacam AXL. Métodos: Se realizó un estudio transversal en 99 ojos de 99 pacientes miopes con criterio de cirugía fotoablativa, atendidos en el período de ...
Taimi Cárdenas Díaz   +4 more
doaj   +2 more sources

Agreement between Scheimpflug-based optical biometer with partial coherence interferometry in patients with keratoconus [PDF]

open access: yesScientific Reports
This study aims to assess the agreement between the Pentacam AXL and IOL Master 500 in measuring biometric components and intraocular lens (IOL) power in patients with keratoconus (KCN).
Hassan Hashemi   +6 more
doaj   +2 more sources

Frequency and Age-Related Changes in Corneal Astigmatism in Cataract Surgery Candidates at a Training Hospital in Turkey [PDF]

open access: yesMedicina
Background and Objectives: To evaluate the magnitude, axis and age-related changes in corneal astigmatism in patients before cataract surgery. Materials and Methods: In this retrospective, cross-sectional, and observational study, data from 2152 eyes ...
Alper Can Yilmaz   +3 more
doaj   +2 more sources

Agreements’ profile of Scheimpflug-based optical biometer with gold standard partial coherence interferometry [PDF]

open access: yesInternational Journal of Ophthalmology, 2023
AIM: To determine the agreement of ocular biometric indices including axial length, keratometric readings, anterior chamber depth, and horizontal corneal diameter between the Pentacam AXL and IOL Master 500. METHODS: The study was a large cross-sectional
Sara Sardari   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy