Results 161 to 170 of about 167,971 (320)
Validation of the Application of Solid Contact Ion-Selective Electrode for Off-Body Sweat Ion Monitoring. [PDF]
Liu H, Gu Z, Liu Y, Xiao X, Xiu G.
europepmc +1 more source
A flow‐through electrochemical membrane reactor equipped with a carbon nanotube membrane eliminates the mass transfer limitation, achieving removals >97.5% for steroid hormone (SH) micropollutants through electrochemical adsorption and degradation, over a broad initial concentration varying from 50 to 106 ng L−1.
Siqi Liu +2 more
wiley +1 more source
Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion‐Selective Electrodes
Zsófia Szigeti +3 more
openalex +2 more sources
This study demonstrates that pulsed potential electrolysis significantly improves CO2 reduction performance on copper‐nitrogen doped carbon electrodes. The formation of cationic copper sites and metallic clusters as a function of applied intermittent potential leads to notable selectivity changes compared to potentiostatic reduction.
Dorottya Hursán +13 more
wiley +1 more source
Two sensitive and selective ion-selective electrodes (ISEs) were developed for the determination of benzydamine hydrochloride (BNZ·HCl): a conventional polyvinyl chloride (PVC) electrode and a coated graphite all solidstate ion-selective electrode (ASS ...
Khadiga M. Kelani +4 more
doaj +1 more source
Modified carbon paste ion selective electrode for determining Cr(iii) ions in aqueous solutions and some real samples using tetragonal zirconia nanoparticles. [PDF]
Fouad OA +4 more
europepmc +1 more source
Fast‐Responding O2 Gas Sensor Based on Luminescent Europium Metal‐Organic Frameworks (MOF‐76)
Luminescent MOF‐76 materials based on Eu(III) and mixed Eu(III)/Y(III) show rapid and reversible changes in emission intensity in response to O2 with very short response times. The effect is based on triplet quenching of the linker ligands that act as photosensitizers. Average emission lifetimes of a few milliseconds turn out to be mostly unaffected by
Zhenyu Zhao +5 more
wiley +1 more source
Effect of Hypoproteinemia on Electrolyte Measurement by Direct and Indirect Ion Selective Electrode Methods. [PDF]
Gohel M, Makadia JS, Chakrabarti C.
europepmc +1 more source
This study presents the BioCLEAR system, a highly transparent and conductive neural electrode array composed of silver nanowires (AgNWs) and doped PEDOT:PSS, enabling neural recordings with minimal optical artifacts. When integrated with a GRIN lens, this cost‐effective neural implant allows simultaneous electrophysiological recording and GCaMP6‐based ...
Dongjun Han +17 more
wiley +1 more source

