Evaluación de la posición del implante iStent inject® mediante gonioscopía y su correlación con la presión intraocular [PDF]
Se realizó un estudio clínico observacional descriptivo de tipo transversal de una serie de pacientes diagnosticados de glaucoma intervenidos con iStent inject en el Servicio de Oftalmología del HURH de Valladolid entre los años 2019 y 2023, a quienes
López Rojas, Carolina
core
Tips and technique for stenting the angle with iStent inject W
Background: Minimally invasive glaucoma surgeries are a breakthrough and have added significantly to the glaucoma surgical armamentarium in the recent past. Angle surgeries, in particular, using the trabecular bypass micro-stents, are one of the safest ones for mild to moderate primary open-angle glaucoma. These
Sushma Tejwani, Ankit A Shah
openaire +1 more source
Experimental study of the stability and flow characteristics of floating liquid columns confined between rotating disks [PDF]
A low Bond number simulation technique was used to establish the stability limits of cylindrical and conical floating liquid columns under conditions of isorotation, equal counter rotation, rotation of one end only, and parallel axis offset.
Fowle, A. A. +3 more
core +1 more source
Minimally Invasive Glaucoma Surgery [PDF]
This open access book covers all aspects of minimally invasive glaucoma surgery (MIGS) and provides detailed information on each MIGS device, including its mechanism of action; patient selection; implantation techniques; post-operative management; and a ...
core +1 more source
Richard Lindstrom, 1 Steven R Sarkisian, 2 Richard Lewis, 3 John Hovanesian, 4 Lilit Voskanyan 5 1Minnesota Eye Consultants, Minneapolis, MN, USA; 2Oklahoma Eye Surgeons, PLLC, Oklahoma City, OK, USA; 3Sacramento Eye Consultants, Sacramento, CA, USA;
Lindstrom R +4 more
doaj
Intraindividuelle Vergleichsstudie in MICS & MIGS: Trabectome vs. iStent inject (K)
29.
Gonnermann, J +5 more
openaire +1 more source
From first generation to the next: evolution and research trends in iStent technology
The iStent series constitutes a range of trabecular bypass minimally invasive glaucoma surgery (MIGS) devices, which offers intraocular pressure (IOP) reduction with favourable safety profiles, in patients with open-angle glaucoma (OAG). Having undergone
Bryan Chin Hou Ang +5 more
doaj +1 more source
Bio-Interventional Cyclodialysis and Allograft Scleral Reinforcement for Uveoscleral Outflow Enhancement in Open-Angle Glaucoma Patients: One-Year Clinical Outcomes. [PDF]
BACKGROUND: To evaluate the one-year safety and effectiveness of bio-interventional cyclodialysis and scleral reinforcement in open-angle glaucoma (OAG) patients undergoing cataract surgery.
Ahmed, Iqbal +7 more
core +2 more sources
Alexandros S Ioannidis, 1, 2 Marc Töteberg-Harms, 3 Timothy Hamann, 3 Christopher Hodge 1, 4, 5 1Vision Eye Institute Blackburn South, Melbourne, VIC, Australia; 2Royal Melbourne Hospital, Melbourne, VIC, Australia; 3Department of Ophthalmology ...
Ioannidis AS +3 more
doaj
Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents
Lutz E Pillunat,1 Carl Erb,2 Anselm GM Jünemann,3 Friedemann Kimmich4 1Department of Ophthalmology, University Hospital Carl Gustav Carus, Dresden, 2Augenklinik am Wittenbergplatz, Berlin, Germany; 3Department of Ophthalmology University of Rostock,
Pillunat LE +3 more
doaj

