Results 71 to 80 of about 34,974 (164)
Purpose The efficacy and safety of the trabecular micro-bypass stents (iStent and iStent inject) have been well documented in various open-angle glaucoma subtypes. However, their outcomes remain understudied in normal-tension glaucoma (NTG).
Ali Salimi +3 more
doaj +1 more source
Real-world savings in medication-related costs up to 5 years with the use of the second-generation trabecular implant (iStent inject®) in mild open-angle glaucoma [PDF]
Objective: To assess medication-related costs in patients with open-angle glaucoma subjected to iStent inject®. Methods: Retrospective study of patients with early-stage open-angle glaucoma who underwent iStent inject® implantation within the Brazilian ...
Ricardo Augusto Paletta Guedes +4 more
doaj +1 more source
Comparison of surgical results between iStent and inject W.
Comparison of surgical results between iStent and inject W.
Yoshihito Sakanishi (17904254) +4 more
core +1 more source
The transition of VF: iStent eyes and inject W eyes.
The transition of VF: iStent eyes and inject W eyes.
Yoshihito Sakanishi (17904254) +4 more
core +1 more source
The transition of BCVA: iStent eyes and inject W eyes.
The transition of BCVA: iStent eyes and inject W eyes.
Yoshihito Sakanishi (17904254) +4 more
core +1 more source
This meta-analysis explores the efficacy and adverse event profile of the iStent, an ab interno implant for the treatment of open-angle glaucoma.A systematic literature search of Ovid MEDLINE and EMBASE was used to identify peer-reviewed original studies that provided efficacy data on the first or second generation iStent for at least five eyes ...
Popovic, Marko +3 more
openaire +2 more sources
Factors affecting cumulative survival: iStent eyes and inject W eyes.
Factors affecting cumulative survival: iStent eyes and inject W eyes.
Yoshihito Sakanishi (17904254) +4 more
core +1 more source
Purpose: To evaluate and compare the early clinical outcomes of five microinvasive glaucoma surgery (MIGS) techniques—Suture-Gonioscopy-Assisted Transluminal Trabeculotomy (Suture-GATT), Kahook Dual Blade (KDB), iStent, Bent Ab Interno Needle Goniectomy (
Prasanna Venkatesh Ramesh +7 more
doaj +1 more source
Background: To assess the safety and efficacy of iStent inject placement in individuals with glaucoma with open angles in real world clinical settings.
Vishal Vohra +2 more
doaj +1 more source
Quality of Life After Combined Cataract and Minimally Invasive Glaucoma Surgery in Glaucoma Patients
Ahmed Al Habash,1 Ahmed A Nagshbandi2 1Department of Ophthalmology, College of Medicine, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia; 2Department of Ophthalmology, Prince Mohammed Bin Abdulaziz ...
Al Habash A, Nagshbandi AA
doaj