Results 251 to 260 of about 24,842,203 (296)
Some of the next articles are maybe not open access.
Nuclear Engineering and Design, 1983
Abstract Tests performed within the framework of earlier RWTUV projects together with results obtained elsewhere with regard to the time dependence of fracture mechanics data show that time effects reduced the toughness of materials, according to the nature of the test (extremely slow load rate or hold times with sustained load).
H.D. Schulze, H. Fuhlrott, G. Togler
openaire +1 more source
Abstract Tests performed within the framework of earlier RWTUV projects together with results obtained elsewhere with regard to the time dependence of fracture mechanics data show that time effects reduced the toughness of materials, according to the nature of the test (extremely slow load rate or hold times with sustained load).
H.D. Schulze, H. Fuhlrott, G. Togler
openaire +1 more source
The J-integral in flexoelectric solids
International Journal of Fracture, 2018The flexoelectric effect is a significant electromechanical coupling phenomenon between strain gradients and electric polarization. Since the design of materials with high flexoelectricity should be accompanied with stress concentration/intensity, the strength and fracture analysis of flexoelectric materials with large strain gradients is desired.
Xinpeng Tian, Qun Li, Qian Deng
openaire +1 more source
J-Integral Estimation Procedures
Journal of Pressure Vessel Technology, 1983This paper presents efficient procedures for estimating the J-integral, a parameter for characterizing stable crack growth under inelastic conditions. Two different formulations are shown. The basis of the first approximate J-integral formula is the familiar extension of the elastic strain energy release rate computation for elastic-plastic loads. This
openaire +1 more source
Experimental measurement of the J-integral
Engineering Fracture Mechanics, 1984Abstract A direct measurement of the J-integral in plane stress state is carried out by utilizing the definition of J as a line integral; the integration function is assessed along a suitable path in rectangular-shaped cracked panels by means of strain gauges.
openaire +1 more source
Analytical Applications of the J-Integral
1973It has recently been shown by experiment that a quantity known as the J-Integral may be a useful fracture criterion in the inelastic range. The mathematical definition of the J-lntegral is first used here, in combination with some simplifying assumptions, to derive the known relationship between the conventional elastic stress concentration factor of a
openaire +1 more source
A study on the dual integral of J
Mechanics Research Communications, 1996Xiao, Q. Z., Wu, C. C., Huang, M. G.
openaire +2 more sources
2003
Write the general expression for the J-integral for anti-plane shear, i.e. mode III. Using the dominant elastic singularity, shrink the J-contour down to the crack tip and prove, by direct calculation ...
openaire +1 more source
Write the general expression for the J-integral for anti-plane shear, i.e. mode III. Using the dominant elastic singularity, shrink the J-contour down to the crack tip and prove, by direct calculation ...
openaire +1 more source
J-integral resistance curve testing and evaluation
Journal of Zhejiang University-SCIENCE A, 2009zbMATH Open Web Interface contents unavailable due to conflicting licenses.
openaire +2 more sources
A New General Integral Transform for Solving Integral Equations
Journal of Advanced Research, 2021Hossein Jafari
exaly
Estimation of J-Integral Uncertainty
1980A method for determining the effect of random experimental error on the calculation of J and crack length extension Δa is presented. Predictor-corrector equations for determining Δa are also derived and their convergence properties studied. The application to a three-point bend specimen is considered and numerical results presented.
openaire +1 more source

